Explore topic-wise MCQs in Electrical Engineering.

This section includes 1232 Mcqs, each offering curated multiple-choice questions to sharpen your Electrical Engineering knowledge and support exam preparation. Choose a topic below to get started.

501.

The crack depth measurement is possible in

A. magnaflux test
B. eddy current test
C. ultrasonic test
D. both b and c
Answer» E.
502.

The result can be recorded by permanently in

A. magnaflux test
B. eddy current test
C. dye penetrant test
D. radiography
Answer» E.
503.

Response of eddy current is depends upon

A. magnetic permeability
B. electrical conductivity
C. structural defects
D. all of the above
Answer» E.
504.

If the care is not taken during magnaflux test then. .... is possible

A. local heating and sparking
B. explosion
C. harmful uv radiation
D. none
Answer» B. explosion
505.

The purpose of developer is to make the penetrant

A. in the crack invisible
B. in the crack visible
C. chemically highly reactive
D. all of the above
Answer» C. chemically highly reactive
506.

The circular cracks are detected in magnaflux test by

A. circular magnetizatio n
B. longitudinal magnetizatio n
C. demagnetiza tion
D. all of the above
Answer» C. demagnetiza tion
507.

The horizontal cracks sre detected in magnaflux test by

A. circular magnetizatio n
B. longitudinal magnetizatio n
C. demagnetiza tion
D. all of the above
Answer» B. longitudinal magnetizatio n
508.

Which one is not a part of magnaflux process?

A. surface preparation
B. magnetizatio n
C. demagnetiza tion
D. observation under microscope
Answer» E.
509.

Principle of operation of eddy current test is based on the

A. development of emf
B. types of current supplied to the material
C. piezoelectrici ty
D. ferroelectrici ty
Answer» B. types of current supplied to the material
510.

Eddy current test may be used to find out

A. defect
B. type of the heat treatment given to material
C. change in chemical composition
D. all of the above
Answer» E.
511.

Which one may be used as material for transducer in ultrasonic test?

A. steel
B. quartz
C. polymer
D. none
Answer» C. polymer
512.

Internal defects inthe steel component cannot be detected by

A. magnaflux
B. radiography
C. ultrasonic
D. none
Answer» B. radiography
513.

Level of liquid in the sealed container may be checked by

A. magnaflux
B. dye penetrant
C. radiography
D. eddy current
Answer» D. eddy current
514.

Dimension and accuracy in the products may be checked by

A. dye penetrant
B. magnaflux
C. radiography
D. eddy current
Answer» E.
515.

Which type of the test is mostly used for the inspection of the grinding and fatigue cracks on tool steeel?

A. magnaflux
B. ultrasonic
C. radiography
D. eddy current
Answer» B. ultrasonic
516.

Oil couplant used in the ultrasonic test to

A. make surface smooth
B. avoid air gap
C. reduce friction
D. fill the surface flaws
Answer» C. reduce friction
517.

........is used to inspect the inside portion of a hollow chamber,narrow tube or a bore

A. boroscope
B. optical microscope
C. endosope
D. telescope
Answer» B. optical microscope
518.

...........is commonly used for visual inspection method

A. boroscope
B. optical microscope
C. endoscope
D. telescope
Answer» C. endoscope
519.

The defects like mould shifts,surface roughness,blow holes etc can be easily detected by ......... method.

A. radiography
B. visual inspection
C. eddy current
D. ultrasonic
Answer» C. eddy current
520.

...........test does not damage the workpiece while testing

A. magnaflu
B. hardness
C. bend
D. torsion
Answer» B. hardness
521.

...........does not damage the workpiece.

A. creep and fatigue
B. brinell and rockwell
C. tensile and erichson test
D. none
Answer» E.
522.

In magnaglo, the wavelength of ultraviolet light is

A. 2500 to 3000a °
B. 3500 to 4000a °
C. 4500 to 5000a °
D. none of the above
Answer» C. 4500 to 5000a °
523.

Detection of subsurfae depends on                    , in MPT

A. the strength of magnetic field
B. the strength of ac magnetic field
C. both a & b
D. none of the above
Answer» B. the strength of ac magnetic field
524.

In MPT, detection of subsurfae depends on

A. the strength of ac magnetic field
B. width of discontinuity
C. the strength of ac voltage
D. none of the above
Answer» C. the strength of ac voltage
525.

                     current magnetization makes it possible to detect surface as well as subsurface discontinuities.

A. ac
B. dc
C. both a & b
D. none of the above
Answer» C. both a & b
526.

In MPT, skin effect comes into picture due to                current

A. ac
B. dc
C. both a & b
D. none of the above
Answer» B. dc
527.

To find out the transverse crack,                        magnetic field has to apply, in MPT

A. lengthwise
B. circular
C. parallel to crack
D. none of the above
Answer» C. parallel to crack
528.

ferromagnetic powder suspended on surface with carrier such as

A. water
B. alcohol
C. keroscene
D. none of the above
Answer» D. none of the above
529.

In MPT, when the part is magnetised                       , transverse cracks are easily detected

A. lengthwise
B. circular
C. parallel to crack
D. none of the above
Answer» B. circular
530.

Select odd options :- Couplant is used in Ultrasonic Testing to

A. remove air gap
B. clean the surface
C. for better contact
D. for lubrication purpose
Answer» C. for better contact
531.

select odd options :- Magnetic partical test is not suitable for

A. gray cast iron
B. chilled cast iron
C. aluminium
D. steel
Answer» D. steel
532.

Internal Discontinuities in the shaft for elctric motor can be checked by

A. ultrasonic testing
B. dye penetrant test
C. magnetic particle test
D. eddy current test
Answer» B. dye penetrant test
533.

Time of travel of waves from the defect is…… for Pulse Echo method

A. more
B. less
C. 1/4 of the total time
D. 1/3 of the toal time
Answer» C. 1/4 of the total time
534.

Which of the following method uses two transducers?

A. pulse echo
B. through transmission
C. eddy current test
D. magnetic particle test
Answer» C. eddy current test
535.

Which of the following method is used for finding the internal defects of material?

A. ultrasonic testing
B. dye penetrant test
C. magnetic particle test
D. eddy current test
Answer» B. dye penetrant test
536.

Which factor of ultrasonic waves is measured in Ultrasonic Testing?

A. wavelength
B. speed of waves
C. time of travel
D. distance traveled
Answer» D. distance traveled
537.

Which of the following method uses the principle of SONAR

A. eddy current test
B. ultrasonic testing
C. x- ray detection
D. ?- ray detection
Answer» C. x- ray detection
538.

Advantages of Non destructive Testings are

A. no surface damage
B. part canbe reused
C. fast method
D. all of the above
Answer» E.
539.

Which of the following tests is a NDT

A. tensile test
B. creep test
C. bend test
D. visual inspection
Answer» E.
540.

Which of the following is not NDT

A. magnetic particle testing
B. dye penetrant test
C. visual inspection
D. vicker\s hardness test
Answer» E.
541.

Specimen can be reused after the NDT

A. immediately
B. never
C. after some treatment
D. can\t say
Answer» E.
542.

For Visual Inspection

A. lower magnificati o n is used
B. higher magnification is used
C. microscope is used
D. non of the above
Answer» B. higher magnification is used
543.

Cleaning of surface is important in DPT

A. required
B. partially required
C. not required
D. none of the above
Answer» B. partially required
544.

DPT is suitable for

A. rolled products
B. cast products
C. powder metallurgy products
D. heterogeneo us components
Answer» B. cast products
545.

DPT cannot be used for

A. plastics
B. metals
C. ceramics
D. can be used for all
Answer» E.
546.

Liquid Penetrant Test is based on the Principle of

A. gravity
B. capillarity
C. partial pressure
D. expansion
Answer» C. partial pressure
547.

Developer is poured........ The penetrant

A. before
B. after
C. at the same time
D. at the start
Answer» C. at the same time
548.

Penetrant comes out of the cracks by

A. surface tension
B. gravity
C. capillarity
D. by external pressure
Answer» B. gravity
549.

Dye Penetrant penetrates inside the crack by

A. surface tension
B. gravity
C. capillarity
D. by external pressure
Answer» D. by external pressure
550.

Internal Defects can be detected by Dye Penetrant Test

A. always
B. never
C. fine internal cracks
D. broad cracks only
Answer» C. fine internal cracks