1. |
Lower values of frequency are used for small machines. |
A. | true |
B. | false |
Answer» C. | |
2. |
What is the dependency of the cost of the armature and field windings with respect to large number of poles? |
A. | high cost for armature windings, low cost for field windings |
B. | high cost for armature windings, high cost for field windings |
C. | low cost for armature windings, high cost for field windings |
D. | low cost for armature windings, low cost for field windings |
Answer» E. | |
3. |
Large number of poles lead to large flashover between brushes. |
A. | true |
B. | false |
Answer» B. false | |
4. |
What is the effect of the distortion of field form with respect to the small number of poles? |
A. | small number of poles cause no distortions |
B. | small number of poles clears all distortions |
C. | small number of poles reduces distortions |
D. | small number of poles increases distortions |
Answer» E. | |
5. |
WHAT_IS_THE_EFFECT_OF_THE_DISTORTION_OF_FIELD_FORM_WITH_RESPECT_TO_THE_SMALL_NUMBER_OF_POLES??$ |
A. | small number of poles cause no distortions |
B. | small number of poles clears all distortions |
C. | small number of poles reduces distortions |
D. | small number of poles increases distortions |
Answer» E. | |
6. |
What is the dependency of the cost of the armature and field windings with respect to large number of poles?$ |
A. | high cost for armature windings, low cost for field windings |
B. | high cost for armature windings, high cost for field windings |
C. | low cost for armature windings, high cost for field windings |
D. | low cost for armature windings, low cost for field windings |
Answer» E. | |
7. |
Large_number_of_poles_lead_to_large_flashover_between_brushes?$ |
A. | true |
B. | false |
Answer» B. false | |
8. |
What should be the armature mmf per pole for output over 1500 kW? |
A. | 5000 A |
B. | 5000-7500 A |
C. | 7500-10000 A |
D. | upto 12500 |
Answer» E. | |
9. |
What should be the range of the current per brush arm? |
A. | limited to 400 A |
B. | limited to 200 A |
C. | limited to 100 A |
D. | limited to 300 A |
Answer» B. limited to 200 A | |
10. |
What is the range of the current per parallel path for the choice of number of poles? |
A. | limited to 100 A |
B. | limited to 150 A |
C. | limited to 200 A |
D. | limited to 250 A |
Answer» D. limited to 250 A | |
11. |
Lower_values_of_frequency_are_used_for_small_machines? |
A. | true |
B. | false |
Answer» C. | |
12. |
What happens to the labor charges when there is an increase in number of poles? |
A. | labor charges are reduced |
B. | labor charges are increased |
C. | labor charges are fixed always |
D. | labor charges vary |
Answer» C. labor charges are fixed always | |
13. |
What happens to the length of the commutators with the increase in number of poles? |
A. | The length of commutators are increased |
B. | The length of commutators are decreased |
C. | The length of commutators are stable |
D. | The length of commutators are higher |
Answer» C. The length of commutators are stable | |
14. |
What happens to the weight of copper in both armature and field windings when the number of poles increase? |
A. | weight of copper in armature winding decreases and weight of copper in field winding increases |
B. | weight of copper in armature winding increases and weight of copper in field winding decreases |
C. | weight of copper in armature winding and field winding decreases |
D. | weight of copper in armature winding and field winding increases |
Answer» D. weight of copper in armature winding and field winding increases | |
15. |
What is the relation of hysteresis loss and weight of iron parts with respect to increase of number of poles? |
A. | decrease in hysteresis loss, increase in weight |
B. | decrease in hysteresis loss, decrease in weight |
C. | increase in hysteresis loss, increase in weight |
D. | increase in hysteresis loss, decrease in weight |
Answer» C. increase in hysteresis loss, increase in weight | |
16. |
What is the range of frequency during the selection of number of poles? |
A. | 20-50 Hz |
B. | 25-40 Hz |
C. | 25-50 Hz |
D. | >50 Hz |
Answer» D. >50 Hz | |
17. |
What is the formula for frequency of flux reversals? |
A. | f = p*n |
B. | f = p/n |
C. | f = n/p |
D. | f = (p*n)/2 |
Answer» E. | |
18. |
How many considerations are present in the selection of number of poles? |
A. | 4 |
B. | 5 |
C. | 6 |
D. | 7 |
Answer» E. | |
19. |
How is the selection of number of poles made in AC and DC machines? |
A. | any number of poles can be used for both AC and DC machines |
B. | fixed number of poles in both AC and DC machines |
C. | fixed number of poles in DC machines and any number of poles in AC machines |
D. | fixed number of poles in AC machines and any number of poles in DC machines |
Answer» E. | |