Explore topic-wise MCQs in Design Electrical Machines.

This section includes 20 Mcqs, each offering curated multiple-choice questions to sharpen your Design Electrical Machines knowledge and support exam preparation. Choose a topic below to get started.

1.

The rotor is slotted for one-third of its periphery.

A. true
B. false
Answer» C.
2.

What is the use of the slot in the rotor?

A. for inserting the field windings
B. for inserting the armature windings
C. for securing the field windings
D. for inserting and securing the field windings
Answer» E.
3.

The overhang has to be highly reinforced in turbo alternators.

A. true
B. false
Answer» B. false
4.

What is the voltage range for large turbo-alternators?

A. 15-20 kV
B. 18-23 kV
C. 20-23 kV
D. 20-25 kV
Answer» E.
5.

What is the use of the laminated and transposed conductors in turbo alternators?

A. to decrease the harmonics
B. to decrease the heating effects
C. to decrease the iron and core loss
D. to decrease the eddy current loss
Answer» E.
6.

WHAT_IS_THE_VOLTAGE_RANGE_FOR_LARGE_TURBO-ALTERNATORS??$

A. 15-20 kV
B. 18-23 kV
C. 20-23 kV
D. 20-25 kV
Answer» E.
7.

WHAT_IS_THE_USE_OF_THE_LAMINATED_AND_TRANSPOSED_CONDUCTORS_IN_TURBO_ALTERNATORS??$

A. to decrease the harmonics
B. to decrease the heating effects
C. to decrease the iron and core loss
D. to decrease the eddy current loss
Answer» E.
8.

What is the use of the slot in the rotor?$

A. for inserting the field windings
B. for inserting the armature windings
C. for securing the field windings
D. for inserting and securing the field windings
Answer» E.
9.

The overhang has to be highly reinforced in turbo alternators?$

A. true
B. false
Answer» B. false
10.

What is the mechanical strength of the end bells used?

A. 1120 MN per m<sup>2</sup>
B. 1130 MN per m<sup>2</sup>
C. 1150 MN per m<sup>2</sup>
D. 1140 MN per m<sup>2</sup>
Answer» D. 1140 MN per m<sup>2</sup>
11.

The rotor is slotted for one-third of its periphery?

A. true
B. false
Answer» C.
12.

How many types are the rotor slots distinguished into?

A. 2
B. 3
C. 4
D. 5
Answer» B. 3
13.

What is the pulsational force produced for 500 MW machine?

A. 70 kN per m
B. 60 kN per m
C. 80 kN per m
D. 90 kN per m
Answer» D. 90 kN per m
14.

What is the advantage of the grain oriented steel laminations?

A. it lowers the iron loss
B. it lowers the core loss
C. it lowers the heating effects
D. it lowers the harmonics
Answer» C. it lowers the heating effects
15.

What type of lamination is used for the stator core of the turbo alternators?

A. stepped
B. smooth
C. interleaved
D. segmental
Answer» E.
16.

What is the outer diameter of the stator core and outer casing of 500 MW turbo alternator?

A. 5 m , 2 m
B. 6 m, 5 m
C. 3 m, 4 m
D. 4 m, 7 m
Answer» D. 4 m, 7 m
17.

What is the core length and the shaft length of a 500 MW turbo alternator?

A. 5 m , 12 m
B. 6 m, 15 m
C. 3 m, 10 m
D. 4 m, 13 m
Answer» B. 6 m, 15 m
18.

What is the relation of the lengths and diameters with the turbo-alternators?

A. long length, long diameters
B. long length, short diameters
C. short lengths, short diameters
D. short lengths, long diameters
Answer» C. short lengths, short diameters
19.

How many poles does the turbo-alternators have and what is the speed of the turbo alternators?

A. 4 poles, 3000 rpm
B. 3 poles, 6000 rpm
C. 2 poles, 5000 rpm
D. 2 poles, 3000 rpm
Answer» E.
20.

How many factors does the construction of the turbo alternators depend upon?

A. 2
B. 4
C. 3
D. 6
Answer» D. 6