			MCQOPTIONS
 Saved Bookmarks
				This section includes 17 Mcqs, each offering curated multiple-choice questions to sharpen your Analytical Instrumentation knowledge and support exam preparation. Choose a topic below to get started.
| 1. | All hydrogen atoms | 
| A. | have the same resonance frequency | 
| B. | resonate at different frequencies depending on their environment. | 
| C. | are attached to carbon | 
| D. | resonate at about the same frequency as carbon | 
| Answer» C. are attached to carbon | |
| 2. | In Spin Decoupler, the output of the DC amplifier is applied to which of the following to control the power supplied to the oven heaters? | 
| A. | Power diode | 
| B. | Power transistor | 
| C. | Power MOSFET | 
| D. | Power IGBT | 
| Answer» C. Power MOSFET | |
| 3. | In order to have a long measuring time for increasing sensitivity, it is better to have several fast scans than a single slow scan. | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 4. | Which of the following is not involved in signal averaging? | 
| A. | A system to repeatedly scan the spectral region of interest | 
| B. | Some storage device to store information | 
| C. | A system to coherently add individual spectra | 
| D. | Sweep generator | 
| Answer» E. | |
| 5. | The amplitude of the NMR signal caused by the absorption of RF energy at the radio frequency does not depend upon the power of the RF energy applied. | 
| A. | True | 
| B. | False | 
| Answer» C. | |
| 6. | Sensitivity is the ratio of peak signal amplitude to which of the following? | 
| A. | Time | 
| B. | Rms noise | 
| C. | Average noise | 
| D. | Peak-to-peak noise | 
| Answer» C. Average noise | |
| 7. | WHICH_OF_THE_FOLLOWING_IS_NOT_INVOLVED_IN_SIGNAL_AVERAGING??$ | 
| A. | A system to repeatedly scan the spectral region of interest | 
| B. | Some storage device to store information | 
| C. | A system to coherently add individual spectra | 
| D. | Sweep generator | 
| Answer» E. | |
| 8. | In Spin Decoupler, the output of the DC amplifier is applied to which of the following to control the power supplied to the oven heaters?$ | 
| A. | Power diode | 
| B. | Power transistor | 
| C. | Power MOSFET | 
| D. | Power IGBT | 
| Answer» C. Power MOSFET | |
| 9. | In_order_to_have_a_long_measuring_time_for_increasing_sensitivity,_it_is_better_to_have_several_fast_scans_than_a_single_slow_scan.$ | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 10. | In Spin Decoupler, the difference frequency circuit provides a means of mixing two signals and a filter to recover which of the following? | 
| A. | Low-frequency component | 
| B. | High-frequency component | 
| C. | Low-voltage component | 
| D. | High-voltage component | 
| Answer» B. High-frequency component | |
| 11. | The amplitude of the NMR signal caused by the absorption of RF energy at the radio frequency does not depend upon the power of the RF energy applied? | 
| A. | True | 
| B. | False | 
| Answer» C. | |
| 12. | Suppression of frequencies which contain no signal does which of the following? | 
| A. | Increases S/N ratio | 
| B. | Decreases S/N ratio | 
| C. | S/N ratio is kept constant | 
| D. | S/N ratio becomes 1 | 
| Answer» B. Decreases S/N ratio | |
| 13. | Frequency spectrum of noise occupies a band that is _________ the signal spectrum. Choose the most appropriate option. | 
| A. | Narrow than | 
| B. | Wider than | 
| C. | Different from | 
| D. | Same as | 
| Answer» C. Different from | |
| 14. | Better sensitivity with good resolution can be achieved by concentrating the sample inside which of the following? | 
| A. | Sample cell | 
| B. | Micro cell | 
| C. | Sample tube | 
| D. | Cylindrical tube | 
| Answer» C. Sample tube | |
| 15. | The most common spherical cells have which of the following dimensions? | 
| A. | 4mm diameter | 
| B. | 40mm diameter | 
| C. | 8mm diameter | 
| D. | 80mm diameter | 
| Answer» B. 40mm diameter | |
| 16. | Which of the following techniques do not enhance sensitivity by a factor of 10 at normal operating conditions? | 
| A. | Optimization of sample volume | 
| B. | Optimization of instrumental parameters | 
| C. | Optimization of noise | 
| D. | Time averaging | 
| Answer» E. | |
| 17. | Which of the following is not an operating technique for sensitivity enhancement? | 
| A. | Optimization of sample volume | 
| B. | Optimization of instrumental parameters | 
| C. | Optimization of noise | 
| D. | Time averaging | 
| Answer» D. Time averaging | |