Explore topic-wise MCQs in Waste Water Engineering.

This section includes 25 Mcqs, each offering curated multiple-choice questions to sharpen your Waste Water Engineering knowledge and support exam preparation. Choose a topic below to get started.

1.

Calculate the tank volume for the Moving bed bioreactor system for the following data.Flow: 80 m3/h.BOD: 300 mg/LRetention time: 6 hrs

A. 500 m3
B. 600 m3
C. 480 m3
D. 120 m3
Answer» D. 120 m3
2.

Calculate the tank volume for the Moving bed bioreactor system for the following data.Flow: 800 m3/h.BOD: 300 mg/LRetention time: 6 hrs

A. 4500 m3
B. 4800 m3
C. 6500 m3
D. 10500 m3
Answer» C. 6500 m3
3.

Calculate the tank volume for the Moving bed bioreactor system for the following data.Flow: 800 m3/h.BOD: 1500 mg/LRetention time: 8 hrs

A. 5000 m3
B. 6400 m3
C. 8400 m3
D. 9200 m3
Answer» C. 8400 m3
4.

Calculate the tank volume for the Moving bed bioreactor system for the following data.Flow: 500 m3/h.BOD: 500 mg/LRetention time: 8 hrs

A. 800 m3
B. 4000 m3
C. 8000 m3
D. 5000 m3
Answer» C. 8000 m3
5.

What is the standard filling degree of MBBR?

A. 50%
B. 55%
C. 67%
D. 72%
Answer» D. 72%
6.

What is the diameter of the cylinder?

A. 5 mm
B. 7.5 mm
C. 10 mm
D. 12 mm
Answer» D. 12 mm
7.

What is the length of the cylinder?

A. 2 mm
B. 5 mm
C. 7 mm
D. 10 mm
Answer» D. 10 mm
8.

What is the shape of the biofilm carrier?

A. Circular
B. Rectangular
C. Square
D. Cylindrical
Answer» E.
9.

The biofilm carrier movement is caused by ________

A. Stirring
B. Horizontal shaft
C. Vertical shaft
D. Agitation by air
Answer» E.
10.

WHAT_IS_THE_SHAPE_OF_THE_BIOFILM_CARRIER??$

A. Circular
B. Rectangular
C. Square
D. Cylindrical
Answer» E.
11.

What is the diameter of the cylinder?$

A. 5 mm
B. 7.5 mm
C. 10 mm
D. 12 mm
Answer» D. 12 mm
12.

What_is_the_length_of_the_cylinder?$

A. 2 mm
B. 5 mm
C. 7 mm
D. 10 mm
Answer» D. 10 mm
13.

What is the combined BOD and nitrogen removal level for moving bed bioreactor?

A. 3-4 Kg BOD/m<sup>3</sup>
B. 2-2.75 Kg BOD/m<sup>3</sup>
C. 5 Kg BOD/m<sup>3</sup>
D. 6 Kg BOD/m<sup>3</sup>
Answer» C. 5 Kg BOD/m<sup>3</sup>
14.

What is the BOD removal level for moving bed bioreactor?

A. 3.5-4.5 Kg BOD/m<sup>3</sup>day
B. 2-2.75 Kg BOD/ m<sup>3</sup>day
C. 3 Kg BOD/ m<sup>3</sup>day
D. 5 Kg BOD/m<sup>3</sup>day
Answer» B. 2-2.75 Kg BOD/ m<sup>3</sup>day
15.

What is the surface area of the media used in these moving bed bioreactor systems?

A. 2000 m<sup>2</sup>
B. 3000 m<sup>2</sup>
C. 200-300 m<sup>2</sup>
D. 400-600 m<sup>2</sup>
Answer» E.
16.

What is the retention time considered for aeration tanks in a moving bed bioreactor system?

A. 4hrs
B. 5-6 hrs
C. 6-8 hrs
D. 8-12 hrs
Answer» D. 8-12 hrs
17.

What_is_the_standard_filling_degree_of_MBBR?

A. 50%
B. 55%
C. 67%
D. 72%
Answer» D. 72%
18.

The biofilm carrier movement is caused by _______?

A. Stirring
B. Horizontal shaft
C. Vertical shaft
D. Agitation by air
Answer» E.
19.

What part of the tank is used by MBBR for biomass growth?

A. 1/ 4
B. 1/ 2
C. 3/ 4
D. 1/ 1
Answer» E.
20.

MBBR was developed based on the activated sludge process and _____

A. Sedimentation process
B. Clarifier process
C. Aeration process
D. Biofilter process
Answer» E.
21.

The ions are desorbed after ______ by the biofilm.

A. Nitrified
B. Denitrified
C. Adsorbed
D. Absorbed
Answer» B. Denitrified
22.

Which ions are present on the charged surface of MBBR?

A. Iron
B. Iodine
C. Aluminium
D. Sodium
Answer» D. Sodium
23.

Which of the following is not correct with respect to MBBR?

A. Compact design
B. Expandable
C. Multiple pass process
D. Load responsive
Answer» D. Load responsive
24.

MBBR needs an assistance to maintain biofilm.

A. True
B. False
Answer» C.
25.

MBBR provides support for both autotrophic and heterotrophic bacteria.

A. True
B. False
Answer» B. False