1.

The diagram of Electrochemical cell used for the detection of hydrogen sulphide is given below. Identify the unmarked component.

A. Filter
B. Gas permeable membrane
C. Elastic layer
D. Electrolyte
Answer» C. Elastic layer
2.

Which of the following is not a component of solid state sensor used for detection of hydrogen sulphide?

A. Heater
B. Thermistor
C. Semiconductor film
D. Photo detector
Answer» E.
3.

In the gold film sensor, the change in resistance is proportional to the concentration of H2S.

A. True
B. False
Answer» B. False
4.

In solid state sensor, when heated to 150o to 300o which of the following occurs?

A. Resistance decreases with increase in H2S concentration
B. Resistance increases with H2S concentration
C. No change in resistance occurs
D. Sensor does not respond in this temperature range
Answer» B. Resistance increases with H2S concentration
5.

Which of the following is not an advantage of solid state sensor used for analysis of H2S?

A. No sampling system
B. It can be used in conditions involving vibration
C. It can be used in corrosive atmosphere
D. No interference from background gases
Answer» E.
6.

WHICH_OF_THE_FOLLOWING_IS_NOT_A_COMPONENT_OF_SOLID_STATE_SENSOR_USED_FOR_DETECTION_OF_HYDROGEN_SULPHIDE??$

A. Heater
B. Thermistor
C. Semiconductor film
D. Photo detector
Answer» E.
7.

Which of the following occurs in Electrochemical cells used for the detection of hydrogen sulphide?

A. Change in resistance
B. Redox reaction
C. Oxidation-reduction reaction
D. Change in colour
Answer» D. Change in colour
8.

In the gold film sensor, the change in resistance is proportional to the concentration of H2S.

A. True
B. False
Answer» B. False
9.

In solid state sensor, when heated to 150o to 300o which of the following occurs?

A. Resistance decreases with increase in H<sub>2</sub>S concentration
B. Resistance increases with H<sub>2</sub>S concentration
C. No change in resistance occurs
D. Sensor does not respond in this temperature range
Answer» B. Resistance increases with H<sub>2</sub>S concentration
10.

Which of the following methods is not used for detection of hydrogen sulphide?

A. Lead acetate tape staining method
B. Solid state sensor
C. Chemiluminescence method
D. Electrochemical cells
Answer» D. Electrochemical cells
11.

Which is the compound that forms the stain in Lead Acetate Tape Staining method used for the analysis of Hydrogen Sulphide and what is the colour of the stain?

A. Lead Sulphide, red colour
B. Lead Sulphide, brown colour
C. Hydrogen acetate, white colour
D. Hydrogen acetate, green colour
Answer» C. Hydrogen acetate, white colour
12.

Which of the following is not an advantage of solid state sensor used for analysis of H2S?

A. No sampling system
B. It can be used in conditions involving vibration
C. It can be used in corrosive atmosphere
D. No interference from background gases
Answer» E.
13.

Which of the following methods are mainly used in combustible gas detection equipment?

A. Lead acetate tape staining method
B. Solid state sensor
C. Gold film sensor
D. Electrochemical cells
Answer» C. Gold film sensor
14.

Which of the following is not an advantage of electrochemical cells used for analysis of H2S?

A. Portable battery operated instrument
B. Pocket sized instrument
C. No pumps are needed
D. No interference from background gases
Answer» E.