1.

What is ‘Z/Sa’ calculation during design of armatures?

A. armature poles/slots
B. armature conductors/slots
C. armature slots/poles
D. armature slots/conductors
Answer» C. armature slots/poles
2.

What should be the range of the integer value while calculating the formula to reduce the flux pulsations?

A. 8-14
B. 9-15
C. 9-16
D. 9-17
Answer» D. 9-17
3.

The number of coils chosen should be minimum in number.

A. true
B. false
Answer» B. false
4.

What is the formula to reduce flux pulsations?

A. armature slot/number of poles = integer
B. armature slot/number of poles = integer + 0.5
C. armature slot/number of poles = integer – 0.5
D. armature slot/number of poles = integer +-0.5
Answer» E.
5.

The choosing of the slot values for armature depends on the type of windings.

A. true
B. false
Answer» B. false
6.

A 4 pole DC machine has 36 number of armature conductors. What is the pole pitch?

A. 9
B. 1/9
C. 92
D. 1/92
Answer» B. 1/9
7.

WHAT_IS_THE_FORMULA_TO_REDUCE_FLUX_PULSATIONS??$

A. armature slot/number of poles = integer
B. armature slot/number of poles = integer + 0.5
C. armature slot/number of poles = integer – 0.5
D. armature slot/number of poles = integer +-0.5
Answer» E.
8.

What should be the range of the integer value while calculating the formula to reduce the flux pulsations?$

A. 8-14
B. 9-15
C. 9-16
D. 9-17
Answer» D. 9-17
9.

The number of coils chosen should be minimum in number?$

A. true
B. false
Answer» B. false
10.

For a DC generator, given the load current is 510 ampere, field current is 1.4 ampere. What is the value of armature current?

A. 508.6 ampere
B. 714 ampere
C. 511.4 ampere
D. 364.28 ampere
Answer» D. 364.28 ampere
11.

Given Z=228 conductors, number of coils C=38 for a DC machine. What is the turns/coils ratio?

A. 4
B. 3
C. 7
D. 3
Answer» E.
12.

What is the formula for calculating the minimum number of coils?

A. Cmin = Voltage
B. Cmin = Voltage/5
C. Cmin = Voltage/10
D. Cmin = Voltage/15
Answer» E.
13.

What is ‘Z/Sa’ calculation during design of armatures?$

A. armature poles/slots
B. armature conductors/slots
C. armature slots/poles
D. armature slots/conductors
Answer» C. armature slots/poles
14.

For a DC machine, the armature slot pitch is 35mm and the diameter is 0.2m. What is the number of armature slots for the machine?

A. 17
B. 18
C. 19
D. 20
Answer» C. 19
15.

What is the range of armature slot pitch in the armature slot design?

A. 20mm – 25mm
B. 25mm – 35mm
C. 30mm – 35mm
D. > 35mm
Answer» C. 30mm ‚Äö√Ñ√∂‚àö√ë‚àö¬® 35mm
16.

What is the condition for choosing the armature current/parallel path in armature design?

A. > 200 ampere for both lap and wave windings
B. >200 ampere for lap winding, <200 ampere for wave winding
C. < 200 ampere for both lap and wave windings
D. <200 ampere for lap winding, >200 ampere for wave winding
Answer» D. <200 ampere for lap winding, >200 ampere for wave winding
17.

The choosing of the slot values for armature depends on the type of windings?

A. true
B. false
Answer» B. false
18.

A 4 pole DC machine has 36 number of armature conductors. What is the pole pitch ?

A. 9
B. 1/9
C. 92
D. 1/92
Answer» B. 1/9
19.

What is the meaning of pole pitch?

A. type of armature slot
B. number of armature slots/pole
C. number of poles/armature slot
D. number of poles/number of armature slots
Answer» C. number of poles/armature slot
20.

Which factor determines the difference between the types of armature windings?

A. brush connection
B. slip ring connection
C. commutator connection
D. pole connection
Answer» D. pole connection
21.

How many type of armature windings are present in the DC machine armature?

A. 2
B. 3
C. 4
D. 5
Answer» B. 3