MCQOPTIONS
Saved Bookmarks
This section includes 10 Mcqs, each offering curated multiple-choice questions to sharpen your Separation Processes knowledge and support exam preparation. Choose a topic below to get started.
1. |
Calculate the sigma factor for the following operating conditionsBowl length L=0.1mRotation rate n=4000/sR0=0.02m, R1=0.01m |
A. | 323 |
B. | 212 |
C. | 234 |
D. | 222 |
Answer» E. | |
2. |
Calculate the sigma factor for the following operating conditionsBowl length L=0.05mRotation rate n=2000/sR0=0.02m, R1=0.01m |
A. | 27 |
B. | 55 |
C. | 111 |
D. | 165 |
Answer» B. 55 | |
3. |
Calculate the sigma factor for the following operating conditionsBowl length L=0.3mRotation rate n=2000/sR0=0.02m, R1=0.01m |
A. | 50 |
B. | 55 |
C. | 111 |
D. | 165 |
Answer» E. | |
4. |
Calculate the sigma factor for the following operating conditionsBowl length L=0.2mRotation rate n=2000/sR0=0.02m, R1=0.01m |
A. | 50 |
B. | 55 |
C. | 111 |
D. | 165 |
Answer» D. 165 | |
5. |
Calculate the sigma factor for the following operating conditionsBowl length L=0.1mRotation rate n=2000/sR0=0.02m, R1=0.01m |
A. | 50 |
B. | 55 |
C. | 111 |
D. | 165 |
Answer» C. 111 | |
6. |
Why are gravity separators not used in bioseparations? |
A. | Because density differences are very large |
B. | Because density differences are very small |
C. | Because gravity separators are too small |
D. | Because the cultures get damaged |
Answer» C. Because gravity separators are too small | |
7. |
When is the basket-filtering centrifuge not used? |
A. | Solids are main product |
B. | Low cake moisture content |
C. | High solid recovery desired |
D. | High liquid recovery desired |
Answer» E. | |
8. |
In which industry tubular-bowl centrifuge not used? |
A. | Food industry |
B. | Pharma industry |
C. | Biochemical industry |
D. | Metallurgical industry |
Answer» E. | |
9. |
What is the use of tubular-bowl centrifuge? |
A. | To separate soap from oil |
B. | To separate waste material |
C. | To separate cells and viruses from broth |
D. | To separate salts from mixtures |
Answer» D. To separate salts from mixtures | |
10. |
What are the two general types of centrifuge devices for solid-liquid separations? |
A. | Sedimentation centrifuges, filtering centrifuges |
B. | Sedimentation centrifuges, decantation centrifuges |
C. | Filtering centrifuges, sintering centrifuges |
D. | Sedimentation centrifuges, two way centrifuges |
Answer» B. Sedimentation centrifuges, decantation centrifuges | |