Explore topic-wise MCQs in Solid State Chemistry.

This section includes 14 Mcqs, each offering curated multiple-choice questions to sharpen your Solid State Chemistry knowledge and support exam preparation. Choose a topic below to get started.

1.

What is the temperature required for the decomposition of CaCO3 in degree Celsius?

A. 200
B. 500
C. 900
D. 1200
Answer» C. 900
2.

The Ti and Tf temperature depends on which of the following factor?

A. Cooling rate
B. Mechanical property of the material
C. Thermal expansion coefficient
D. Atmosphere above the sample
Answer» E.
3.

Under conditions of ______________ heating, decomposition usually take place in thermogravimetry. Fill up the suitable option from the choices given below.

A. First order
B. Second order
C. Third order
D. Dynamic
Answer» E.
4.

What is the range of the rate in ◦Cmin-1 required during the heating process in TGA?

A. 1-20
B. 25-50
C. 100-200
D. 150-1000
Answer» B. 25-50
5.

THE_TI_AND_TF_TEMPERATURE_DEPENDS_ON_WHICH_OF_THE_FOLLOWING_FACTOR??$

A. Cooling rate
B. Mechanical property of the material
C. Thermal expansion coefficient
D. Atmosphere above the sample
Answer» E.
6.

What_is_the_temperature_required_for_the_decomposition_of_CaCO3_in_degree_Celsius?$

A. 200
B. 500
C. 900
D. 1200
Answer» C. 900
7.

Under conditions of ______________ heating, decomposition usually take place in thermogravimetry. Fill up the suitable option from the choices given below?

A. First order
B. Second order
C. Third order
D. Dynamic
Answer» E.
8.

What is the range of the rate in ‚ó¶Cmin-1 required during the heating process in TGA?$

A. 1-20
B. 25-50
C. 100-200
D. 150-1000
Answer» B. 25-50
9.

In thermogravimetric analysis, the result obtained appear as a __________

A. Continuous chart
B. Continuous parabola
C. Continuous circular positions
D. Discontinuous chart
Answer» B. Continuous parabola
10.

Which of the following statements given below is false?

A. TGA, DTA and DSC are measured using same instrument
B. TGA and DTA can be carried out simultaneously.
C. TGA, DTA and DSC are measured using different instruments.
D. TMA is a recent name of Dilatometry.
Answer» D. TMA is a recent name of Dilatometry.
11.

Dilatometry is also known as by which of the following names?

A. TGA
B. DTA
C. DSC
D. TMA
Answer» E.
12.

What are the two main techniques for thermal analysis?

A. FTG AND DGG
B. MSP AND FCT
C. TGA AND DTA
D. TSA AND DGF
Answer» D. TSA AND DGF
13.

Which of the following method can be used for the measurement of change in weight of the oxysalts?

A. Thermoelectric analysis
B. Wagner analysis
C. Stockbarger analysis
D. Thermal analysis
Answer» E.
14.

Thermal analysis is defined as ___________

A. Measurement of concentration of materials as a function of temperature
B. Measurement of solubility of materials as a function of temperature
C. Measurement of physical properties as a function of temperature
D. Measurement of line positions of crystals as a function of temperature
Answer» D. Measurement of line positions of crystals as a function of temperature