Explore topic-wise MCQs in Testing Subject.

This section includes 657 Mcqs, each offering curated multiple-choice questions to sharpen your Testing Subject knowledge and support exam preparation. Choose a topic below to get started.

1.

The approximate particle size of microcapsule using solvent evaporation is:

A. 5-5000 µm
B. 100-10,000 µm
C. 10-100 µm
D. 5-10 µm
Answer» B. 100-10,000 µm
2.

Find the correct one.

A. 000 largest size
B. 00 Largest size
C. 5 smallest size
D. Both A and C are correct
Answer» E.
3.

A retardant material that forms a hydrophilic matrix in the formulation of matrix tablets is.

A. HPMC
B. CAP
C. Polyethylene
D. Carnauba wax
Answer» B. CAP
4.

Crown thickness of the tablet is measured by

A. Micrometer
B. Hydrometer
C. Pychnometer
D. Any one of the above
Answer» D. Any one of the above
5.

Unless otherwise stated in the individual monograph of the pharmacopoeia, in the disintegration test forenteric coated tablets, first the dissolution is carried out in.

A. 0.1N HCl
B. Phosphate buffer
C. water
D. 0.1 M H2SO4
Answer» D. 0.1 M H2SO4
6.

Type A gelatin has its isoelectric point in the region of

A. pH 4.7
B. pH 9.0
C. pH 7.4
D. pH 9.4
Answer» C. pH 7.4
7.

The first and most widely used diluent in tablet formulation is

A. Dextrose
B. Lactose
C. MCC
D. Starch
Answer» C. MCC
8.

Anhydrous lactose has advantage over hydrous lactose.

A. Improved flow
B. Absence of milliard reaction
C. Improved Compressibility
D. High microbial load
Answer» C. Improved Compressibility
9.

The main aim of package inserts or leaflets is:

A. To provide information essential for the safe and effective use of the drugs
B. Reducing the number of adverse reactions
C. Adequate direction of use
D. All of the above
Answer» E.
10.

Which of the following ingredient is used for polishing of sugar coated tablets

A. Gelatin
B. Talc
C. PEG 4000
D. Carnauba wax
Answer» E.
11.

Which of the following is used to fill powdered dry solid into soft gelatin capsules?

A. Accogel
B. Rotofil
C. Rotosort
D. Rotoweigh
Answer» B. Rotofil
12.

Whiskering (a tablet defect) is observed with the use of _____ punch.

A. Convex
B. Flat
C. Concave
D. Biconvex
Answer» D. Biconvex
13.

Enteric coated tablet disintegrate in

A. Stomach
B. Liver
C. Intestine
D. Mouth
Answer» D. Mouth
14.

Sealing of capsules is achieved by:

A. 100 °C
B. 20 °C
C. 37 °C – 40 °C
D. 70 °C
Answer» D. 70 °C
15.

____________ treatment is used for the solubility of gelatin.

A. Heat
B. Formalin
C. Alcohol
D. Formalin
Answer» C. Alcohol
16.

Viscosity of gelatin ranges from:

A. 8-10 millipoise
B. 60-80 millipoise
C. 2-10 millipoise
D. 25-45 millipoise
Answer» E.
17.

In capsules, Elancofil and accofil machine is used for

A. Filling of powder into capsules
B. Filling pellets into capsules
C. Sorting filled capsule
D. Filling liquids into capsules
Answer» B. Filling pellets into capsules
18.

Enteric coated tablet disintegrate in ____ hrs in simulated intestinal fluid.

A. 1
B. 2
C. 3
D. 4
Answer» C. 3
19.

_______ is used for bulk handling, warehouse storage and transport shipping. The most common form is a palletized unit load that packs tightly into containers.

A. Primary packaging
B. Tertiary packaging
C. Quaternary packaging
D. Secondary packaging
Answer» C. Quaternary packaging
20.

Rotosort is used for

A. Sorting filled capsules
B. Filling the capsule
C. Mixing of powder
D. None of the above
Answer» B. Filling the capsule
21.

What is the name of the phase transition that occurs when a solid is converted directly into a gas (without going through the liquid phase)?

A. Melting
B. Boiling
C. Condensing
D. Sublimation
Answer» E.
22.

Apparatus 1 as per USP:

A. Flow-through cell
B. Paddle
C. Basket
D. Reciprocating cylinder
Answer» D. Reciprocating cylinder
23.

Low melting point substances causes processing problem in tablets. Identify it.

A. Poor Flow
B. Weight variation
C. Sticking
D. Picking
Answer» D. Picking
24.

In dissolution test, flask is maintained at:

A. 31° C ± 0.5C
B. 41° C ± 0.1C
C. 39° C ± 0.6C
D. 40° C ± 0.1C
Answer» B. 41° C ± 0.1C
25.

“Pink” color coding is used for which class of pharmaceutical products?

A. Antibiotics
B. Beta blockers
C. Steroids
D. Anti-infectives
Answer» D. Anti-infectives
26.

What’s the role of cam tracks in tablet compression machines?

A. For proper movement of the punches
B. For proper movement of the granules
C. For proper movement of both (granules and punches)
D. For movement of granules and hopper
Answer» B. For proper movement of the granules
27.

Larger values of Ky in the Heckel Plot indicate formation of what quality of tablets?

A. Harder tablets
B. Soft tablets
C. Brittle tablets
D. Fluffy tablets
Answer» B. Soft tablets
28.

Powered glass test used for the standardization of which type of glass material:

A. Type I, II & III
B. Type I, III, IV
C. Type II, III, IV
D. All of the above
Answer» C. Type II, III, IV
29.

Boxes and cartons are covered in which type of packaging in pharmaceutical?

A. Primary
B. Secondary
C. Tertiary
D. Quaternary
Answer» C. Tertiary
30.

Base for chewable tablets include

A. Mannitol
B. Glucose
C. Lactose
D. None
Answer» B. Glucose
31.

Durability of a tablet to combined effects of shock and abrasion is evaluated by using.

A. Hardness tester
B. Disintegration test apparatus
C. Friabilator
D. Screw gauge
Answer» D. Screw gauge
32.

Empty capsule has moisture content in the range of

A. 60%
B. 12-15%
C. 50-70%
D. 30%
Answer» D. 30%
33.

Aerosil is used as a:

A. Glidant
B. Lubricant
C. Antiadherent
D. None
Answer» B. Lubricant
34.

Correct test for standardization of rubber material

A. Leakage test/ Collapsibility
B. Powder glass test
C. Fragmentation test
D. Hydraulic test
Answer» D. Hydraulic test
35.

Which of the following is a synthetic adhesive?

A. PVP
B. MC
C. HPMC
D. HPC
Answer» B. MC
36.

What is Primogel?

A. Substituted HPMC for direct compression
B. Modified MCC for direct compression
C. Hydrogelling polymer for gel formation
D. Modified starch for disintegration
Answer» E.
37.

What is different in B tooling and D tooling?

A. Punch and die length are different
B. Punch length same but die length different
C. Punch and die diameter are different
D. Punch diameter same but die diameter different
Answer» D. Punch diameter same but die diameter different
38.

Iron content of gelatin for hard and soft gelatin capsule:

A. NMT 5 ppm
B. NMT 10 ppm
C. NMT 25 ppm
D. NMT 15 ppm
Answer» E.
39.

Packaging Testing includes:

A. Shock test and drop test
B. Vibration test
C. Inclined Impact test
D. All of the above
Answer» E.
40.

Which one of these is responsible for hardness of tablet?

A. Die Filling
B. Compression force
C. Both (a) & (b)
D. None of these
Answer» D. None of these
41.

____________ decreases the bioavailability of tetracycline.

A. Lactose
B. DCP
C. Starch
D. MCC
Answer» C. Starch
42.

Enteric coated tablet is dissolved in 0.1 N HCl as per I.P.

A. 180 minutes
B. 120 minutes
C. 45 minutes
D. 60 minutes
Answer» C. 45 minutes
43.

Which one is the example of Opacifier

A. TiO2
B. MgO
C. Silicates
D. None of the above
Answer» B. MgO
44.

Gelatin and glycerin are used for the preparation of lamellae in a specified ratio. Identify the correctratio.

A. 1:1
B. 5:1
C. 9:1
D. 10:1
Answer» D. 10:1
45.

Weight variation limits as per USP for the tablet weight more than 324 mg:

A. 7.5 mg
B. 7.5%
C. 5%
D. 5 mg
Answer» D. 5 mg
46.

Enteric resin used for coating is?

A. Cellulose acetate Pthalate
B. Zein
C. Shellac
D. All of the above
Answer» D. All of the above
47.

Use of colloidal silicone dioxide in tablet formulation:

A. Diluent
B. Disintegrant
C. Glidant
D. Lubricant
Answer» D. Lubricant
48.

Which machine is designed for filling of pellets?

A. Rotofil
B. Rotosort
C. Ordinary machine
D. None of these
Answer» B. Rotosort
49.

Which tablet compression machine is best for compression of granules?

A. Single Press
B. Longitudinal Press
C. Rotary Press
D. Stamping press
Answer» D. Stamping press
50.

How many tablets require for content uniformity test

A. 10
B. 20
C. 30
D. 40
Answer» D. 40