Explore topic-wise MCQs in Control Systems.

This section includes 15 Mcqs, each offering curated multiple-choice questions to sharpen your Control Systems knowledge and support exam preparation. Choose a topic below to get started.

1.

The sinusoid x(t) =6cos10πt is sampled at the rate of 15 Hz and applied to ideal rectangular LPF with cut-off frequency of 10 Hz, then the output of filter contains:

A. Only 10π rad/sec component
B. 10π rad/sec component
C. 10π rad/sec and 20π rad/sec components
D. +10π rad/sec and +20π rad/sec components
Answer» C. 10π rad/sec and 20π rad/sec components
2.

A digital measuring instrument employs a sampling rate of 100 samples/second. The sampled input x(n) is averaged using the difference equation:Y (n) =[x (n)+x (n-1)+x(n-2)+x(n-4)/4]For a step input, the maximum time taken for the output to reach the final value after the input transition is

A. 20 ms
B. 40 ms
C. 80 ms
D.
Answer» C. 80 ms
3.

An LTI system having transfer function s2+1/s2+2s+1 and input x(t) =sin(t+1) is in steady state. The output is sampled at ws rad/s to obtain the final output {y (k)}. Which of the following is true?

A. Y is zero for all sampling frequencies ws
B. Y is non zero for all sampling frequencies ws
C. Y is non zero for ws>2 but zero for ws<2
D. Y is zero for ws>2 but non zero for ws<2
Answer» B. Y is non zero for all sampling frequencies ws
4.

A signal represented by x(t) =5cos 400πt is sampled at a rate 300 samples/sec. The resulting samples are passed through an ideal low pass filter of cut-off frequency 150 Hz. Which of the following will be contained in the output of the LPF?

A. 100 Hz
B. 100 Hz, 150 Hz
C. 50 Hz, 100 Hz
D. 50 Hz, 100 Hz, 150 Hz
Answer» B. 100 Hz, 150 Hz
5.

Statement (I): Aliasing occurs when the sampling frequency is less than twice the maximum frequency in the signal.Statement (II): Aliasing is a reversible process.

A. Both statement (I) and Statement (II) are individually true and Statement (II) is the correct explanation of Statement (I).
B. Both Statement (I) and Statement (II) are individually true but Statement (II) is not correct explanation of Statement (I)
C. Statement (I) is true but Statement (II) is false
D. Statement (I) is False but Statement (II) is true
Answer» D. Statement (I) is False but Statement (II) is true
6.

A_DIGITAL_MEASURING_INSTRUMENT_EMPLOYS_A_SAMPLING_RATE_OF_100_SAMPLES/SECOND._THE_SAMPLED_INPUT_X(N)_IS_AVERAGED_USING_THE_DIFFERENCE_EQUATION:?$

A. =[x (n)+x (n-1)+x(n-2)+x(n-4)/4] For a step input, the maximum time taken for the output to reach the final value after the input transition is
B. 20 ms
C. 40 ms
D. 80 ms
Answer» C. 40 ms
7.

The_sinusoid_x(t)_=6cos10πt_is_sampled_at_the_rate_of_15_Hz_and_applied_to_ideal_rectangular_LPF_with_cut-off_frequency_of_10_Hz,_then_the_output_of_filter_contains:$#

A. Only 10π rad/sec component
B. 10π rad/sec component
C. 10π rad/sec and 20π rad/sec components
D. +10π rad/sec and +20π rad/sec components
Answer» C. 10‚âà√¨‚àö√ë rad/sec and 20‚âà√¨‚àö√ë rad/sec components
8.

An LTI system having transfer function s2+1/s2+2s+1 and input x(t) =sin(t+1) is in steady state. The output is sampled at ws rad/s to obtain the final output {y (k)}. Which of the following is true?

A. Y is zero for all sampling frequencies ws
B. Y is non zero for all sampling frequencies ws
C. Y is non zero for ws>2 but zero for ws<2
D. Y is zero for ws>2 but non zero for ws<2
Answer» B. Y is non zero for all sampling frequencies ws
9.

A signal m(t) with bandwidth 500 Hz is first multiplied by a signal g(t). The resulting signal is passed through an ideal low pass filter with bandwidth 1 kHz. The output of the low pass filter would be :

A. Impulse
B. m(t)
C. 0
D. m(t)del(t)
Answer» D. m(t)del(t)
10.

A signal represented by x(t) =5cos 400πt is sampled at a rate 300 samples/sec. The resulting samples are passed through an ideal low pass filter of cut-off frequency 150 Hz. Which of the following will be contained in the output of the LPF?$

A. 100 Hz
B. 100 Hz, 150 Hz
C. 50 Hz, 100 Hz
D. 50 Hz, 100 Hz, 150 Hz
Answer» B. 100 Hz, 150 Hz
11.

A bandpass sampling extends from 4-6 kHz. What is the smallest sampling frequency required to retain all the information in the signal.

A. 1 kHz
B. 2 kHz
C. 3 kHz
D. 4 kHz
Answer» E.
12.

Increased pulse-width in the flat-top sampling leads to:

A. Attenuation of high frequencies in reproduction
B. Attenuation of low frequencies in reproduction
C. Greater aliasing errors in reproduction
D. No harmful effects in reproduction
Answer» B. Attenuation of low frequencies in reproduction
13.

Let x(t) be a continuous-time, real valued signal band-limited to F Hz. The Nyquist sampling rate in Hz, For y(t) =x(0.5t) +x(t)-x(2t) is

A. F
B. 2F
C. 4F
D. 8F
Answer» D. 8F
14.

A band limited signal with a maximum frequency of 5 KHz to be sampled. According to the sampling theorem, the sampling frequency which is not valid is:

A. 5 KHz
B. 12 KHz
C. 15 KHz
D. 20 KHz
Answer» B. 12 KHz
15.

Statement (I): Aliasing occurs when the sampling frequency is less than twice the maximum frequency in the signal.

A. : Aliasing is a reversible process.
B. Both statement (I) and Statement (II) are individually true and Statement (II) is the correct explanation of Statement (I).
C. Both Statement (I) and Statement (II) are individually true but Statement (II) is not correct explanation of Statement (I)
D. Statement (I) is true but Statement (II) is false
Answer» D. Statement (I) is true but Statement (II) is false