1.

In ultrasonic inspection, there is no chance of rejection of good material.

A. True
B. False
Answer» C.
2.

Monitoring of porosity defects in casting by ultrasonic inspection is very difficult.

A. True
B. False
Answer» B. False
3.

In ultrasonic inspection, some standards are taken as a reference to measure the size of discontinuity in the material.

A. True
B. False
Answer» B. False
4.

Which of the following formulas is used for the calculation of ultrasonic attenuation coefficient ( )?

A. = 10 log(A<sub>0</sub>/A)/X
B. = 20 log(A<sub>0</sub>/A)*X
C. = 10 log(A<sub>0</sub>/A)*X
D. = 20 log(A<sub>0</sub>/A)/X
Answer» E.
5.

Ultrasound attenuation has no affects on the detection of discontinuities or defects in the castings.

A. True
B. False
Answer» C.
6.

Coarse grained structures of casting material lead to increase attenuation in ultrasonic inspection.

A. True
B. False
Answer» B. False
7.

In MPI method, the magnetic discontinuities lie in a direction parallel to the direction of the magnetic field.

A. True
B. False
Answer» C.