Explore topic-wise MCQs in Prestressed Concrete Structures.

This section includes 20 Mcqs, each offering curated multiple-choice questions to sharpen your Prestressed Concrete Structures knowledge and support exam preparation. Choose a topic below to get started.

1.

The codal provision for reinforcement cover is?

A. IS: 1343-2012
B. IS: 1347-2014
C. IS: 1342-2006
D. IS: 1340-2008
Answer» B. IS: 1347-2014
2.

The nominal cover provided for steel to obtain most effective fire resistance is according to ___________

A. 1992-1-2004
B. 1994-1-2006
C. 1996-1-2005
D. 1998-1-2008
Answer» B. 1994-1-2006
3.

The nominal cover provided for moderate steel is ___________

A. 30
B. 20
C. 40
D. 50
Answer» B. 20
4.

The permissible stress in prestressing steel should not exceed ___________

A. 80%
B. 60%
C. 50%
D. 70%
Answer» B. 60%
5.

The prevention of hydrogen embrittlement can be done by protecting the wires from ___________

A. Rain water and humidity
B. Reactions and shocks
C. Heat
D. Deflection
Answer» B. Reactions and shocks
6.

The atomic hydrogen is liberated as a result of the action of ___________

A. Sulphur
B. Manganese
C. Acids
D. Stresses
Answer» D. Stresses
7.

Hard-drawn steel wires used in high tensile steel are considered as ___________

A. Crimped elements
B. Twisted elements
C. Durable elements
D. Tempered elements
Answer» B. Twisted elements
8.

The properties of cold-drawing through wires can be improved by heating at ___________

A. 100-320 degrees
B. 130-400 degrees
C. 150-480 degrees
D. 120-380 degrees
Answer» D. 120-380 degrees
9.

The high tensile steel is obtained by increasing content of ___________

A. Carbon content in steel
B. Aluminium content in steel
C. Manganese content in steel
D. Sulphur content in steel
Answer» B. Aluminium content in steel
10.

The ultimate strength of high tensile steel is ___________

A. 1100
B. 2100
C. 1500
D. 1250
Answer» C. 1500
11.

THE_NOMINAL_COVER_PROVIDED_FOR_STEEL_TO_OBTAIN_MOST_EFFECTIVE_FIRE_RESISTANCE_IS_ACCORDING_TO:?$

A. 1992-1-2004
B. 1994-1-2006
C. 1996-1-2005
D. 1998-1-2008
Answer» B. 1994-1-2006
12.

The_codal_provision_for_reinforcement_cover_is?$

A. IS: 1343-2012
B. IS: 1347-2014
C. IS: 1342-2006
D. IS: 1340-2008
Answer» B. IS: 1347-2014
13.

The nominal cover provided for moderate steel is?

A. 30
B. 20
C. 40
D. 50
Answer» B. 20
14.

The permissible stress in prestressing steel should not exceed:

A. 80%
B. 60%
C. 50%
D. 70%
Answer» B. 60%
15.

The prevention of hydrogen embrittlement can be done by protecting the wires from:

A. Rain water and humidity
B. Reactions and shocks
C. Heat
D. Deflection
Answer» B. Reactions and shocks
16.

The atomic hydrogen is liberated as a result of action of:

A. Sulphur
B. Manganese
C. Acids
D. Stresses
Answer» D. Stresses
17.

Hard-drawn steel wires used in high tensile steel are considered as:

A. Crimped elements
B. Twisted elements
C. Durable elements
D. Tempered elements
Answer» B. Twisted elements
18.

The properties of cold-drawing through wires can be improved by heating at:

A. 100-320degrees
B. 130-400degrees
C. 150-480degrees
D. 120-380degrees
Answer» D. 120-380degrees
19.

The high tensile steel is obtained by increasing content of:

A. Carbon content in steel
B. Aluminium content in steel
C. Manganese content in steel
D. Sulphur content in steel
Answer» B. Aluminium content in steel
20.

The ultimate strength of high tensile steel is:

A. 1100
B. 2100
C. 1500
D. 1250
Answer» C. 1500