

MCQOPTIONS
Saved Bookmarks
This section includes 20 Mcqs, each offering curated multiple-choice questions to sharpen your Prestressed Concrete Structures knowledge and support exam preparation. Choose a topic below to get started.
1. |
The design of joint should allow __________ |
A. | Retardation |
B. | Translation |
C. | Sublimination |
D. | Axial |
Answer» C. Sublimination | |
2. |
Another example of application of prestressed concrete in buildings can be seen in construction of __________ |
A. | 11 – storied structure |
B. | 13 – storied structure |
C. | 10 – storied structure |
D. | 15 – storied structure |
Answer» B. 13 – storied structure | |
3. |
Prestressed hollow inverted pyramids have been used as a transfer in? |
A. | Girder system |
B. | Flange system |
C. | Block system |
D. | Chain system |
Answer» B. Flange system | |
4. |
The prestressed concrete folded plate units are also widely used to cover roofs of __________ |
A. | Industrial buildings |
B. | Commercial buildings |
C. | Structural buildings |
D. | Regional buildings |
Answer» B. Commercial buildings | |
5. |
The precast pretensioned cored slabs having circular or elliptical cavities have been used in __________ |
A. | France |
B. | Russia |
C. | Phillipines |
D. | Losangles |
Answer» C. Phillipines | |
6. |
The use of concrete trusses with modular coordination for spans of 6and 9 are common for countries like? |
A. | America |
B. | Poland |
C. | India |
D. | Nueziland |
Answer» C. India | |
7. |
The depth of diagonal web members is at a range of __________ |
A. | 100-150 |
B. | 200-250 |
C. | 110-210 |
D. | 114-115 |
Answer» B. 200-250 | |
8. |
The bottom tie member should be sufficient size to __________ |
A. | Tension |
B. | Stress |
C. | House |
D. | Strain |
Answer» D. Strain | |
9. |
The width of various components is kept constant at __________ |
A. | 100-200mm |
B. | 200-350mm |
C. | 150-300mm |
D. | 1200-1400mm |
Answer» C. 150-300mm | |
10. |
The span of trusses generally lies in the range of __________ |
A. | 18-30m |
B. | 20-30m |
C. | 40-50m |
D. | 12-18m |
Answer» B. 20-30m | |
11. |
ANOTHER_EXAMPLE_OF_APPLICATION_OF_PRESTRESSED_CONCRETE_IN_BUILDINGS_CAN_BE_SEEN_IN_CONSTRUCTION_OF:?$ |
A. | 11 – storied structure |
B. | 13 – storied structure |
C. | 10 – storied structure |
D. | 15 – storied structure |
Answer» B. 13 ‚Äö√Ñ√∂‚àö√ë‚àö¬® storied structure | |
12. |
The_design_of_joint_should_allow:$ |
A. | Retardation |
B. | Translation |
C. | Sublimination |
D. | Axial |
Answer» C. Sublimination | |
13. |
Prestressed hollow inverted pyramids have been used as a transfer? |
A. | Girder system |
B. | Flange system |
C. | Block system |
D. | Chain system |
Answer» B. Flange system | |
14. |
The prestressed concrete folded plate units are also widely used to cover roofs of: |
A. | Industrial buildings |
B. | Commercial buildings |
C. | Structural buildings |
D. | Regional buildings |
Answer» B. Commercial buildings | |
15. |
The precast pretensioned cored slabs having circular or elliptical cavities have been used in: |
A. | France |
B. | Russia |
C. | Phillipines |
D. | Losangles |
Answer» C. Phillipines | |
16. |
The use of concrete trusses with modular coordination for spans of 6and 9 are common for countries like: |
A. | America |
B. | Poland |
C. | India |
D. | Nueziland |
Answer» C. India | |
17. |
The depth of diagonal web members is at a range of: |
A. | 100-150 |
B. | 200-250 |
C. | 110-210 |
D. | 114-115 |
Answer» B. 200-250 | |
18. |
The bottom tie member should be sufficient size to: |
A. | Tension |
B. | Stress |
C. | House |
D. | Strain |
Answer» D. Strain | |
19. |
The width of various components is kept constant at: |
A. | 100-200mm |
B. | 200-350mm |
C. | 150-300mm |
D. | 1200-1400mm |
Answer» C. 150-300mm | |
20. |
The span of trusses generally lies in the range of: |
A. | 18-30m |
B. | 20-30m |
C. | 40-50m |
D. | 12-18m |
Answer» B. 20-30m | |