			MCQOPTIONS
 Saved Bookmarks
				This section includes 29 Mcqs, each offering curated multiple-choice questions to sharpen your Engineering Metrology knowledge and support exam preparation. Choose a topic below to get started.
| 1. | Which type of special purpose system is used for the examination of hazardous process or for extreme radiations? | 
| A. | Fibrescope | 
| B. | Chamberscope | 
| C. | Periscope | 
| D. | Vacuum borescope | 
| Answer» D. Vacuum borescope | |
| 2. | Where does the CCD chip is placed in flexible fiberscope? | 
| A. | At proximal end | 
| B. | Ar median point | 
| C. | At the distal end | 
| D. | Anywhere between proximal and distal end | 
| Answer» D. Anywhere between proximal and distal end | |
| 3. | Which of the following is not true about rigid chamberscope? | 
| A. | Enable use of extension tube | 
| B. | Have zoom facility | 
| C. | Used for rapid inspection | 
| D. | Offer greater magnification | 
| Answer» B. Have zoom facility | |
| 4. | For what distance, videoscopes are used with CCD probes for electronic transmission? | 
| A. | Less than 15 m | 
| B. | More than 15 m | 
| C. | Less than 10 m | 
| D. | More than 10 m | 
| Answer» C. Less than 10 m | |
| 5. | Which of the following option is true for the given statements about flexible fibrescope?Statement 1: Fibrescope produce higher resolution than videoscope.Statement 2: Videoscopes have longer working length than fibrescope. | 
| A. | T, T | 
| B. | T, F | 
| C. | F, F | 
| D. | F, T | 
| Answer» E. | |
| 6. | Visual inspection is essentially carried out using a magnifying glass. | 
| A. | True | 
| B. | False | 
| Answer» C. | |
| 7. | Positive surface irregularity is caused by excess metal penetration. | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 8. | Which subject classification of the MFFT has the characteristics, long time spending and high errors making? | 
| A. | Fast-accurates | 
| B. | Slow-inaccurates | 
| C. | Reflectives | 
| D. | Impulsives | 
| Answer» C. Reflectives | |
| 9. | Which subject classification of the MFFT has the characteristics, short time spending and few errors making? | 
| A. | Fast-accurates | 
| B. | Slow-inaccurates | 
| C. | Reflectives | 
| D. | Impulsives | 
| Answer» B. Slow-inaccurates | |
| 10. | Which subject classification of the MFFT has the characteristics, long time spending and less errors making? | 
| A. | Fast-accurates | 
| B. | Slow-inaccurates | 
| C. | Reflectives | 
| D. | Impulsives | 
| Answer» D. Impulsives | |
| 11. | What does M.F.F.T. stand for? | 
| A. | Maximum Flow Filling Temperature | 
| B. | Minimum Flow Filling Temperature | 
| C. | Minimum Film Forming Temperature | 
| D. | Maximum Film Forming Temperature | 
| Answer» D. Maximum Film Forming Temperature | |
| 12. | POSITIVE_SURFACE_IRREGULARITY_IS_CAUSED_BY_EXCESS_METAL_PENETRATION.?$ | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 13. | FOR_WHAT_DISTANCE,_VIDEOSCOPES_ARE_USED_WITH_CCD_PROBES_FOR_ELECTRONIC_TRANSMISSION??$ | 
| A. | Less than 15 m | 
| B. | More than 15 m | 
| C. | Less than 10 m | 
| D. | More than 10 m | 
| Answer» C. Less than 10 m | |
| 14. | Where does the CCD chip is placed in flexible fiberscope?$ | 
| A. | At proximal end | 
| B. | Ar median point | 
| C. | At the distal end | 
| D. | Anywhere between proximal and distal end | 
| Answer» D. Anywhere between proximal and distal end | |
| 15. | Visual_inspection_is_essentially_carried_out_using_a_magnifying_glass.$ | 
| A. | True | 
| B. | False | 
| Answer» C. | |
| 16. | Which_of_the_following_is_not_true_about_rigid_chamberscope?$ | 
| A. | Enable use of extension tube | 
| B. | Have zoom facility | 
| C. | Used for rapid inspection | 
| D. | Offer greater magnification | 
| Answer» B. Have zoom facility | |
| 17. | Which of the following is not true for rigid borescopes? | 
| A. | Operates like telescope in reverse | 
| B. | Good for rapid examination | 
| C. | Video adaptation is present | 
| D. | Semi Rigid sheathing is present | 
| Answer» E. | |
| 18. | Which_type_of_special_purpose_system_is_used_for_the_examination_of_hazardous_process_or_for_extreme_radiations? | 
| A. | Fibrescope | 
| B. | Chamberscope | 
| C. | Periscope | 
| D. | Vacuum borescope | 
| Answer» D. Vacuum borescope | |
| 19. | Negative surface irregularities cannot be caused by which of the following factor? | 
| A. | Slag inclusion | 
| B. | Oxidation pitting | 
| C. | Nitride pitting | 
| D. | Shrinkage | 
| Answer» D. Shrinkage | |
| 20. | Which of the following cannot be detected using visual inspection? | 
| A. | Blowholes | 
| B. | Crack within the cast | 
| C. | Tears | 
| D. | Rattails | 
| Answer» C. Tears | |
| 21. | Upto which length the flexible fiberscopes are available? | 
| A. | 12 m | 
| B. | 14 m | 
| C. | 16 m | 
| D. | 18 m | 
| Answer» B. 14 m | |
| 22. | Which of the following option is true about hybrid borescopes? | 
| A. | Use rod lenses combined with concave lenses | 
| B. | Use rod lenses combined with concave mirror | 
| C. | Use rod lenses combined with convex lenses | 
| D. | Use rod lenses combined with convex mirror | 
| Answer» D. Use rod lenses combined with convex mirror | |
| 23. | What type of fibre is present in the optical tube of mini borescope? | 
| A. | Quartz fibre | 
| B. | Asbestos fibre | 
| C. | Plastic fibre | 
| D. | Resin fibre | 
| Answer» B. Asbestos fibre | |
| 24. | What is the field of view range of borescope? | 
| A. | 30 to 180 degree | 
| B. | 10 to 90 degree | 
| C. | 60 to 360 degree | 
| D. | 10 to 180 degree | 
| Answer» C. 60 to 360 degree | |
| 25. | Which subject classification of the MFFT has the characteristics, short time spending and high errors making? | 
| A. | Fast-accurates | 
| B. | Slow-inaccurates | 
| C. | Reflectives | 
| D. | Impulsives | 
| Answer» E. | |
| 26. | What is the use of fluorescent penetrants? | 
| A. | Develop permanent visual records of a remote object | 
| B. | Illuminates and observes internal, closed or inaccessible areas | 
| C. | Enhance the observation of surface cracks | 
| D. | Evaluate surface finish, shape and microstructure | 
| Answer» D. Evaluate surface finish, shape and microstructure | |
| 27. | Which of the following was not a classification of a subject taking the MFFT? | 
| A. | Slow accurates | 
| B. | Slow in-accurates | 
| C. | Fast-Accurates | 
| D. | Reflectives | 
| Answer» B. Slow in-accurates | |
| 28. | What is the tube diameter of rigid borescope? | 
| A. | 0.1 to 10 mm | 
| B. | 0.5 to 90 mm | 
| C. | 0.2 to 100 mm | 
| D. | 0.9 to 70 mm | 
| Answer» E. | |
| 29. | What is the use of an interference microscope? | 
| A. | Measure depth of scratches | 
| B. | Measure width of crack | 
| C. | Develop a permanent visual record | 
| D. | Only illuminate the cracks | 
| Answer» B. Measure width of crack | |