| 1. | If the two metals have different temperature coefficient then, they are useful in making _________ | 
| A. | Manometric thermometer | 
| B. | Gas thermometer | 
| C. | Bimetallic thermometer | 
| D. | Digital thermometer | 
| Answer» D. Digital thermometer | |
| 2. | Antifoam probe is a type of off-line sensor. | 
| A. | True | 
| B. | False | 
| Answer» C. | |
| 3. | Ion-specific sensors are the types of on-line sensors. | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 4. | Which of the following parameters is not useful in the construction of pressure bellows? | 
| A. | Hysteresis | 
| B. | Sensitive to changing pressures | 
| C. | Corrosion | 
| D. | pH | 
| Answer» E. | |
| 5. | Which of the following sensor is not a part of the fermenter? | 
| A. | On-line | 
| B. | In-line | 
| C. | Off-line | 
| D. | Out-line | 
| Answer» D. Out-line | |
| 6. | Which of the following measures the pressure with change in electrical resistance? | 
| A. | Bourdon tube | 
| B. | Pressure bellows | 
| C. | Strain gauge | 
| D. | Diaphragm gauge | 
| Answer» D. Diaphragm gauge | |
| 7. | Who invented the Bourdon tube? | 
| A. | Eugene | 
| B. | Howe | 
| C. | Flynn | 
| D. | Royce | 
| Answer» B. Howe | |
| 8. | Which of the following devices is not used for pressure measurement? | 
| A. | Diaphragm gauge | 
| B. | Pressure bellows | 
| C. | Strain gauge | 
| D. | Dynamometer | 
| Answer» E. | |
| 9. | Which of the following is made up of mixtures of pure oxides of iron and nickel? | 
| A. | Thermistors | 
| B. | Mercury thermometers | 
| C. | Radiation thermometers | 
| D. | Metallic thermometers | 
| Answer» B. Mercury thermometers | |
| 10. | The resistance _________ with increase in temperature. | 
| A. | Increases | 
| B. | Decreases | 
| C. | Becomes constant | 
| D. | Becomes zero | 
| Answer» B. Decreases | |
| 11. | Which of the following temperature sensors is not used for a temperature measurement? | 
| A. | Non-electrical type | 
| B. | Electrical type | 
| C. | Magnetic type | 
| D. | Radiation type | 
| Answer» D. Radiation type | |
| 12. | The heat control at large-scale in the fermenter is carried out by _________ | 
| A. | Inter heating coils | 
| B. | Heating jacket | 
| C. | Controlled bath | 
| D. | Cold-water circulation | 
| Answer» E. | |
| 13. | Which of the following sensor is used to measure the change in flow rate? | 
| A. | Temperature | 
| B. | Weight | 
| C. | Medium analysis | 
| D. | Exit-gas analysis | 
| Answer» C. Medium analysis | |
| 14. | Which of the following sensor is used to measure the acid/alkali addition? | 
| A. | pH | 
| B. | Redox | 
| C. | Temperature | 
| D. | Oxygen | 
| Answer» B. Redox | |
| 15. | Which of the following sensor penetrates into the fermenter? | 
| A. | Exhaust-gas analyzers | 
| B. | pH electrodes | 
| C. | Tachometers | 
| D. | Load cells | 
| Answer» C. Tachometers | |