1.

A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by auto transformer method of starting with a tapping ratio of ‘x’, then the starting torque will be?

A. x *Tfl
B. x^2 *Tfl
C. 1/x *Tfl
D. no change in the starting current
Answer» B. x^2 *Tfl
2.

A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by auto transformer method of starting with a tapping ratio of ‘x’, then the starting current reduces by?

A. x
B. x^2
C. 1/x
D. no change in the starting current
Answer» C. 1/x
3.

A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by reactance method of starting with a fraction of ‘x’, then the starting torque reduces by?

A. x
B. x^2
C. 1/x
D. no change in the starting current
Answer» C. 1/x
4.

A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by reactance method of starting with a fraction of ‘x’, then the starting current reduces by?

A. x
B. x^2
C. 1/x
D. no change in the starting current
Answer» B. x^2