 
			 
			MCQOPTIONS
 Saved Bookmarks
				This section includes 26 Mcqs, each offering curated multiple-choice questions to sharpen your Power Plant knowledge and support exam preparation. Choose a topic below to get started.
| 1. | Which of these factors don’t cause Internal Irreversibility of a Rankine cycle? | 
| A. | Throttling | 
| B. | Mixing | 
| C. | Fluid Friction | 
| D. | Fluid flow | 
| Answer» E. | |
| 2. | Phase change at constant pressure takes place in _____________ | 
| A. | Economiser | 
| B. | Evaporator | 
| C. | Superheater | 
| D. | Air-Preheater | 
| Answer» D. Air-Preheater | |
| 3. | In Rankine Cycle, water is converted to saturated liquid in ___________ | 
| A. | Evaporator | 
| B. | Economizer | 
| C. | Superheater | 
| D. | Preheater | 
| Answer» C. Superheater | |
| 4. | Which is the most common type of Evaporator? | 
| A. | Flooded Evaporator | 
| B. | Plate Evaporator | 
| C. | Coil Evaporator | 
| D. | Brine Evaporator | 
| Answer» C. Coil Evaporator | |
| 5. | Steam Power Plants are more popular in electric power generation because ___________ | 
| A. | Work output of turbine is very large than work input to the pump | 
| B. | Work output of turbine is very small than work input to the pump | 
| C. | Work output of turbine is equal to work input to the pump | 
| D. | None of the mentioned | 
| Answer» B. Work output of turbine is very small than work input to the pump | |
| 6. | Efficiency of a Rankine Cycle is also expressed as __________ | 
| A. | Capacity Ratio | 
| B. | Heat Rate | 
| C. | Heat Ratio | 
| D. | Steam Rate | 
| Answer» C. Heat Ratio | |
| 7. | In a Rankine Cycle, heat output is obtained from ___________ | 
| A. | Condenser | 
| B. | Boiler | 
| C. | Turbine | 
| D. | Pump | 
| Answer» B. Boiler | |
| 8. | In a Rankine Cycle, heat input is provided to ___________ | 
| A. | Condenser | 
| B. | Pump | 
| C. | Turbine | 
| D. | Boiler | 
| Answer» E. | |
| 9. | The net work done in a Rankine Cycle is the difference of _____________ | 
| A. | Condenser work & Boiler work | 
| B. | Boiler work & Pump work | 
| C. | Turbine Work & Pump work | 
| D. | Condenser work & Pump work | 
| Answer» D. Condenser work & Pump work | |
| 10. | For analytical purposes, the Rankine Cycle is assumed to be in _____________ | 
| A. | Unsteady flow operation | 
| B. | Turbulent flow operation | 
| C. | Steady flow operation | 
| D. | Laminar flow operation | 
| Answer» D. Laminar flow operation | |
| 11. | Ideal ‘Rankine Cycle’ is a __________ process. | 
| A. | Reversible | 
| B. | Irreversible | 
| C. | Reversible & Irreversible | 
| D. | None of the mentioned | 
| Answer» B. Irreversible | |
| 12. | EFFICIENCY_OF_A_RANKINE_CYCLE_IS_ALSO_EXPRESSED_AS__________?$ | 
| A. | Capacity Ratio | 
| B. | Heat Rate | 
| C. | Heat Ratio | 
| D. | Steam Rate | 
| Answer» C. Heat Ratio | |
| 13. | The most common type of Evaporator is?$ | 
| A. | Flooded Evaporator | 
| B. | Plate Evaporator | 
| C. | Coil Evaporator | 
| D. | Brine Evaporator | 
| Answer» C. Coil Evaporator | |
| 14. | Steam_Power_Plants_are_more_popular_in_electric_power_generation_because$ | 
| A. | Work output of turbine is very large than work input to the pump | 
| B. | Work output of turbine is very small than work input to the pump | 
| C. | Work output of turbine is equal to work input to the pump | 
| D. | None of the mentioned. | 
| Answer» B. Work output of turbine is very small than work input to the pump | |
| 15. | Which of these factors don’t cause Internal Irreversibility of a Rankine cycle?$ | 
| A. | Throttling | 
| B. | Mixing | 
| C. | Fluid Friction | 
| D. | Fluid flow | 
| Answer» E. | |
| 16. | Phase change at constant pressure takes place in? | 
| A. | Economiser | 
| B. | Evaporator | 
| C. | Superheater | 
| D. | Air-Preheater | 
| Answer» D. Air-Preheater | |
| 17. | If Evaporator & Condenser pressures are p & q, the intercooler pressure P is given as? | 
| A. | P=pq | 
| B. | P=p/q | 
| C. | P=(pq)<sup>(1/2)</sup> | 
| D. | P=p<sup>2</sup>q | 
| Answer» D. P=p<sup>2</sup>q | |
| 18. | In_Rankine_Cycle,_water_is_converted_to_saturated_liquid_in____________ | 
| A. | Evaporator | 
| B. | Economizer | 
| C. | Superheater | 
| D. | Preheater | 
| Answer» C. Superheater | |
| 19. | Which of these is sometimes neglected? | 
| A. | Turbine work | 
| B. | Pump work | 
| C. | Condenser heat | 
| D. | Boiler heat | 
| Answer» C. Condenser heat | |
| 20. | Steam Rate is the reciprocal of _________ | 
| A. | Net work done | 
| B. | Heat extracted from condenser | 
| C. | Heat given to reciprocal | 
| D. | Work done by turbine. | 
| Answer» B. Heat extracted from condenser | |
| 21. | The water that flows from the Pump is? | 
| A. | Compressible | 
| B. | Incompressible | 
| C. | Unsteady | 
| D. | None of the mentioned | 
| Answer» C. Unsteady | |
| 22. | In a Rankine Cycle, heat output is obtained from? | 
| A. | Condenser | 
| B. | Boiler | 
| C. | Turbine | 
| D. | Pump | 
| Answer» B. Boiler | |
| 23. | In a Rankine Cycle, heat input is provided to? | 
| A. | Condenser | 
| B. | Pump | 
| C. | Turbine | 
| D. | Boiler | 
| Answer» E. | |
| 24. | The net work done in a Rankine Cycle is the difference of? | 
| A. | Condenser work & Boiler work | 
| B. | Boiler work & Pump work | 
| C. | Turbine Work & Pump work | 
| D. | Condenser work & Pump work | 
| Answer» D. Condenser work & Pump work | |
| 25. | For analytical purposes, the Rankine Cycle is assumed to be in? | 
| A. | Unsteady flow operation | 
| B. | Turbulent flow operation | 
| C. | Steady flow operation | 
| D. | Laminar flow operation | 
| Answer» D. Laminar flow operation | |
| 26. | Ideal ‘Rankine Cycle’ is a __________ process. | 
| A. | Reversible | 
| B. | Irreversible | 
| C. | Both of the mentioned | 
| D. | None of the mentioned | 
| Answer» B. Irreversible | |