Explore topic-wise MCQs in Power Plant.

This section includes 15 Mcqs, each offering curated multiple-choice questions to sharpen your Power Plant knowledge and support exam preparation. Choose a topic below to get started.

1.

Which of these is not a property of MHD power generation?

A. has no moving part, so is reliable
B. overall generation cost is less
C. closed cycle has almost no pollution
D. conversion is about 80-90%
Answer» E.
2.

Which is the only fuel better than coal for use?

A. natural gas
B. char
C. kerosene
D. benzene
Answer» C. kerosene
3.

Which of these materials are not used for MHD duct walls?

A. magnesium oxide
B. strontium zirconate
C. hafnia
D. manganese zirconate
Answer» B. strontium zirconate
4.

The air at the entrance of MHD duct is seeded with potasium upto ____________

A. 7%
B. 5%
C. 3%
D. 1%
Answer» E.
5.

In an open cycle MHD-steam power plant, the temperature at the entrance of MHD duct is (in K)?

A. 2500-3000
B. 2000-2500
C. 1500-2000
D. 2250
Answer» B. 2000-2500
6.

WHICH_IS_THE_ONLY_FUEL_BETTER_THAN_COAL_FOR_USE??$

A. natural gas
B. char
C. kerosene
D. benzene
Answer» C. kerosene
7.

Which_of_these_is_not_a_property_of_MHD_power_generation?$

A. has no moving part, so is reliable
B. overall generation cost is less
C. closed cycle has almost no pollution
D. conversion is about 80-90%
Answer» E.
8.

To reduce the power consumption of electromagnets, which type of coils have been suggested?

A. cryogenic
B. high temperature resistant
C. superconducting
D. aluminium
Answer» B. high temperature resistant
9.

Which of these materials not used for MHD duct walls?

A. magnesium oxide
B. strontium zirconate
C. hafnia
D. manganese zirconate
Answer» B. strontium zirconate
10.

Where is the input of the MHD duct heated in a closed cycle MHD-steam power plant?

A. blast furnace
B. nuclear reactor
C. reverabatory furnace
D. combustion chamber
Answer» C. reverabatory furnace
11.

In closed cycle MHD-steam power plant, which of the following gas is seeded in the MHD duct?

A. helium
B. xenon
C. sodium vapour
D. chlorine
Answer» B. xenon
12.

Which of the following device helps in recovery of seeding element?

A. ion precipitator
B. condenser
C. electrostatic precipitator
D. orsat’s apparatus
Answer» D. orsat‚Äö√Ñ√∂‚àö√ë‚àö¬•s apparatus
13.

Air pollution in an MHD-steam power plant is caused due to the formation of which of the following compounds?

A. oxides and hydroxides
B. chlorides and hydroxides
C. oxides and carbonates
D. carbonates and bicarbonates
Answer» B. chlorides and hydroxides
14.

The air at the entrance of MHD duct is seeded with potasium upto

A. 7%
B. 5%
C. 3%
D. 1%
Answer» E.
15.

In an open cycle MHD-steam power plant, the temperature at the entrance of MHD duct is (in K)

A. 2500-3000
B. 2000-2500
C. 1500-2000
D. 2250
Answer» B. 2000-2500