1. |
A mass-spring damper system with force as input and displacement of the mass as output has a transfer function\(G\left( s \right) = \frac{1}{{\left( {{s^2} + 24\;s + 900} \right)}}\)A force input F(t) = 10 sin (70 t) newtons is applied at time t = 0 s. A beam from an optical stroboscope is focused on the mass. In steady state, the strobe frequency in hertz at which the mass appears to be stationary is |
A. | \(\frac{5}{\pi }\) |
B. | \(\frac{{15}}{\pi }\) |
C. | \(\frac{{35}}{\pi }\) |
D. | \(\frac{{50}}{\pi }\) |
Answer» D. \(\frac{{50}}{\pi }\) | |
2. |
WHICH_OF_THE_FOLLOWING_STATEMENT_IS_TRUE_FOR_DIAPHRAGMS??$ |
A. | Used for measuring small forces |
B. | Used for measuring large forces |
C. | Used for measuring dynamic forces |
D. | None of the mentioned |
Answer» B. Used for measuring large forces | |
3. |
Load cells are primary transducers.$ |
A. | True |
B. | False |
Answer» B. False | |
4. |
Which of the following statement is true for force? |
A. | Force is a scalar quantity |
B. | Force is a vector quantity |
C. | Force is a dimensionless quantity |
D. | None of the mentioned |
Answer» C. Force is a dimensionless quantity | |
5. |
Diaphragm element can also be used for force measurement. |
A. | True |
B. | False |
Answer» B. False | |
6. |
Which of the following conversion is correct for load cell? |
A. | Force to strain |
B. | Force to displacement |
C. | Force to voltage |
D. | Both force to strain and force to displacement |
Answer» E. | |
7. |
Which of the following represents correct relationship for strain in ring-type load cell? |
A. | (1.08 F R)/(E b t<sup>2</sup> ) |
B. | ( F R)/(E b t<sup>2</sup> ) |
C. | (1.08 R)/(E b t<sup>2</sup> ) |
D. | (1.08 F )/(E b t<sup>2</sup> ) |
Answer» B. ( F R)/(E b t<sup>2</sup> ) | |
8. |
Which of the following arrangements are used in load cells? |
A. | Tensile strain gauges |
B. | Compressive strain gauges |
C. | Both tensile and compressive strain gauges |
D. | None of the mentioned |
Answer» D. None of the mentioned | |
9. |
Which of the following can be measured using Ring-type load cell? |
A. | Large weight |
B. | Small weight |
C. | Both large and small weights |
D. | None of the mentioned |
Answer» C. Both large and small weights | |
10. |
Load cells are used for measuring_______________ |
A. | Large weights only |
B. | Small weights only |
C. | Weights moving in high speed |
D. | Slowly moving weights |
Answer» E. | |
11. |
Which of the following device can be used for force measurement? |
A. | Beams |
B. | Bellows |
C. | Capsule |
D. | Bourdon tube |
Answer» B. Bellows | |