Explore topic-wise MCQs in Electronic Devices and Circuits Questions and Answers.

This section includes 6 Mcqs, each offering curated multiple-choice questions to sharpen your Electronic Devices and Circuits Questions and Answers knowledge and support exam preparation. Choose a topic below to get started.

1.

Find the ft required for internally compensated op amps to be used in the implementation of the closed loop amplifiers with dc gain of -2 V/V and 3db bandwidth of 10 MHz?

A. 7.5 MHz
B. 15 MHz
C. 22.5 MHz
D. 30 MHz
Answer» E.
2.

A particular op amp, characterized by a gain–bandwidth product of 20 MHz, is operated with a closed-loop gain of +100 V/V. What 3-dB bandwidth results? At what frequency does the closed-loop amplifier exhibit a −6° phase shift?

A. 21 kHz
B. 31.5 kHz
C. 42 kHz
D. 52.5 kHz
Answer» B. 31.5 kHz
3.

An inverting amplifier with nominal gain of −20 V/V employs an op amp having a dc gain of 104 and a unity-gain frequency of 106 Hz. What is the 3-dB frequency f3dB of the closed-loop amplifier?

A. 2π 23.8 kHz
B. 2π 47.6 kHz
C. 2π 71.4 kHz
D. 2π 95.2 kHz
Answer» C. 2π 71.4 kHz
4.

An internally compensated op amp has a dc open-loop gain of 106 V/V and an AC open-loop gain of 40 dB at 10 kHz. Estimate its gain–bandwidth product and its expected gain at 1 kHz.

A. 0.1 MHz and -60 db
B. 10 MHz and -60 db
C. 10 MHz and 60 db
D. 1 MHz and 60 db
Answer» E.
5.

An op amp having a 106-dB gain at dc and a single-pole frequency response with ft = 2 MHz is used to design a non-inverting amplifier with nominal dc gain of 100. The 3-dB frequency of the closed-loop gain is

A. 10 kHz
B. 20 kHz
C. 30 kHz
D. 40 kHz
Answer» C. 30 kHz
6.

An internally compensated op amp is specified to have an open-loop dc gain of 106 dB and a unity gain bandwidth of 3 MHz. Find fb and the open-loop gain at fb.

A. 15Hz and 103 db
B. 30Hz and 103 db
C. 15 Hz and 51.5 db
D. 30 Hz and 51.5 db
Answer» B. 30Hz and 103 db