MCQOPTIONS
Saved Bookmarks
This section includes 6 Mcqs, each offering curated multiple-choice questions to sharpen your Electronic Devices and Circuits Questions and Answers knowledge and support exam preparation. Choose a topic below to get started.
1. |
Find the ft required for internally compensated op amps to be used in the implementation of the closed loop amplifiers with dc gain of -2 V/V and 3db bandwidth of 10 MHz? |
A. | 7.5 MHz |
B. | 15 MHz |
C. | 22.5 MHz |
D. | 30 MHz |
Answer» E. | |
2. |
A particular op amp, characterized by a gain–bandwidth product of 20 MHz, is operated with a closed-loop gain of +100 V/V. What 3-dB bandwidth results? At what frequency does the closed-loop amplifier exhibit a −6° phase shift? |
A. | 21 kHz |
B. | 31.5 kHz |
C. | 42 kHz |
D. | 52.5 kHz |
Answer» B. 31.5 kHz | |
3. |
An inverting amplifier with nominal gain of −20 V/V employs an op amp having a dc gain of 104 and a unity-gain frequency of 106 Hz. What is the 3-dB frequency f3dB of the closed-loop amplifier? |
A. | 2π 23.8 kHz |
B. | 2π 47.6 kHz |
C. | 2π 71.4 kHz |
D. | 2π 95.2 kHz |
Answer» C. 2π 71.4 kHz | |
4. |
An internally compensated op amp has a dc open-loop gain of 106 V/V and an AC open-loop gain of 40 dB at 10 kHz. Estimate its gain–bandwidth product and its expected gain at 1 kHz. |
A. | 0.1 MHz and -60 db |
B. | 10 MHz and -60 db |
C. | 10 MHz and 60 db |
D. | 1 MHz and 60 db |
Answer» E. | |
5. |
An op amp having a 106-dB gain at dc and a single-pole frequency response with ft = 2 MHz is used to design a non-inverting amplifier with nominal dc gain of 100. The 3-dB frequency of the closed-loop gain is |
A. | 10 kHz |
B. | 20 kHz |
C. | 30 kHz |
D. | 40 kHz |
Answer» C. 30 kHz | |
6. |
An internally compensated op amp is specified to have an open-loop dc gain of 106 dB and a unity gain bandwidth of 3 MHz. Find fb and the open-loop gain at fb. |
A. | 15Hz and 103 db |
B. | 30Hz and 103 db |
C. | 15 Hz and 51.5 db |
D. | 30 Hz and 51.5 db |
Answer» B. 30Hz and 103 db | |