MCQOPTIONS
Saved Bookmarks
This section includes 122 Mcqs, each offering curated multiple-choice questions to sharpen your Power Systems knowledge and support exam preparation. Choose a topic below to get started.
51. |
Direct conversion of heat into electrical energy is possible through |
A. | fuel cells |
B. | solar cells |
C. | MHD generators |
D. | none of the above |
Answer» D. none of the above | |
52. |
Direct conversion of heat into electric power is possible through |
A. | fuel cell |
B. | batteries |
C. | thermionic converter |
D. | all of the above |
Answer» D. all of the above | |
53. |
Which lightening stroke is most dangerous ? |
A. | Direct stroke on line conductor |
B. | Indirect stroke on conductor |
C. | Direct stroke on tower top |
D. | Direct stroke on ground wire |
Answer» B. Indirect stroke on conductor | |
54. |
Which of the following source of power is least reliable ? |
A. | Solar energy |
B. | Geothermal power |
C. | Wind power |
D. | MHD |
Answer» D. MHD | |
55. |
A pilot exciter is provided on generators for which of the following reasons ? |
A. | To excite the poles of main exciter |
B. | To provide requisite starting torque to main exciter |
C. | To provide requisite starting torque to generator |
D. | None of the above |
Answer» B. To provide requisite starting torque to main exciter | |
56. |
In which?of the following power plants the maintenance cost is usually high? |
A. | Nuclear power plant |
B. | Hydro-electric power plants |
C. | Thermal power plants |
D. | Diesel engine power plants |
Answer» D. Diesel engine power plants | |
57. |
A consumer has to pay lesser fixed charges in |
A. | flat rate tariff |
B. | two part tariff |
C. | maximum demand tariff |
D. | any of the above |
Answer» D. any of the above | |
58. |
Low power factor is usually not due to |
A. | Arc lamps |
B. | Induction motors |
C. | Fluorescent tubes |
D. | Incandescent lamp |
Answer» E. | |
59. |
Incase of ______ fuel transportation is the major problem. |
A. | diesel power plants |
B. | nuclear power plants |
C. | hydro-electric power plants |
D. | thermal power plants |
Answer» E. | |
60. |
With reference to a power station which of the following is not a fixed cost? |
A. | Fuel cost |
B. | Interest on capital |
C. | Insurance charges |
D. | Depreciation |
Answer» B. Interest on capital | |
61. |
Which of the following, in a thermal power plant, is not a fixed cost? |
A. | Fuel cost |
B. | Interest on capital |
C. | Depreciation |
D. | Insurance charges |
Answer» B. Interest on capital | |
62. |
For which of the following power plants highly skilled engineers are required for running the plants? |
A. | Nuclear power plants |
B. | Gas turbine power plants |
C. | Solar power plants |
D. | Hydro-electric power plants |
Answer» B. Gas turbine power plants | |
63. |
For the same cylinder dimensions and speed, which of the following engine will produce least power? |
A. | Supercharged engine |
B. | Diesel engine |
C. | Petrol engine |
D. | All of the above engines will equal power |
Answer» D. All of the above engines will equal power | |
64. |
Static capacitors are rated in terms of |
A. | kW |
B. | kWh |
C. | kVAR |
D. | none of the above |
Answer» D. none of the above | |
65. |
The connected load of a IVMIM uir consumer is around |
A. | 5 kW |
B. | 40 kV |
C. | 80 kW |
D. | 120 kW |
Answer» B. 40 kV | |
66. |
The area under a load curve gives |
A. | average demand |
B. | energy consumed |
C. | maximum demand |
D. | none of the above |
Answer» C. maximum demand | |
67. |
Which of the following is not a method for estimating depreciation charges? |
A. | Sinking fund method |
B. | Straight line method |
C. | Diminishing value method |
D. | Halsey |
Answer» E. | |
68. |
A low utilization factor for a plant indicates that |
A. | plant is used for stand by purpose only |
B. | plant is under maintenance |
C. | plant is used for base load only |
D. | plant is used for peak load as well as base load |
Answer» B. plant is under maintenance | |
69. |
In a power plant if the maximum demand on the plant is equal to the plant capacity, then |
A. | Plant reserve capacity will be zero |
B. | Diversity factor will be unity |
C. | Load factor will be unity |
D. | Load factor will be nearly 60% |
Answer» B. Diversity factor will be unity | |
70. |
Which of the following is not necessarily an advantage of interconnecting various power stations? |
A. | Improved frequency of power supplied |
B. | Reduction in total installed capacity |
C. | Increased reliability |
D. | Economy in operation of plants |
Answer» B. Reduction in total installed capacity | |
71. |
Which of the following is the disadvantage due to low power factor ? |
A. | Poor voltage regulation |
B. | Increased transmission losses |
C. | High cost of equipment for a given load |
D. | All of the above |
Answer» E. | |
72. |
Which of the following devices may be used to provide protection against lightening over voltages ? |
A. | Horn gaps |
B. | Rod gaps |
C. | Surge absorbers |
D. | All of the above |
Answer» E. | |
73. |
power plant cannot have single unit of 100 MW. |
A. | Hydroelectric |
B. | Nuclear |
C. | Steam |
D. | Diesel |
E. | Any of the above |
Answer» E. Any of the above | |
74. |
In India production and distribution of electrical energy is confined to |
A. | private sector |
B. | public sector |
C. | government sectors |
D. | joint sector |
E. | none of the above |
Answer» C. government sectors | |
75. |
An over excited synchronous motor on noload is known as |
A. | synchronous condenser |
B. | generator |
C. | induction motor |
D. | alternator |
Answer» B. generator | |
76. |
Annual depreciation cost is calculated by |
A. | sinkingfund method |
B. | straight line method |
C. | both (A) and (B) |
D. | none of the above |
Answer» D. none of the above | |
77. |
In Hopknison demand rate or two parttariff the demand rate or fixed charges are |
A. | dependent upon the energy consumed |
B. | dependent upon the maximum demand of the consumer |
C. | both (A) and (B) |
D. | neither (A) nor (B) |
Answer» C. both (A) and (B) | |
78. |
By the use of which of the following power factor can be improved ? |
A. | Phase advancers |
B. | Synchronous compensators |
C. | Static capacitors |
D. | Any of the above |
Answer» E. | |
79. |
Annual depreciation as per straight line method, is calculated by |
A. | the capital cost divided by number of year of life |
B. | the capital cost minus the salvage value, is divided by the number of years of life |
C. | increasing a uniform sum of money per annum at stipulated rate of interest |
D. | none of the above |
Answer» C. increasing a uniform sum of money per annum at stipulated rate of interest | |
80. |
High load factor indicates |
A. | cost of generation per unit power is increased |
B. | total plant capacity is utilised for most of the time |
C. | total plant capacity is not properly utilised for most of the time |
D. | none of the above |
Answer» C. total plant capacity is not properly utilised for most of the time | |
81. |
The increased load during summer months is due to |
A. | increased business activity |
B. | increased water supply |
C. | increased use of fans and air conditioners |
D. | none of the above |
Answer» D. none of the above | |
82. |
A load curve indicates |
A. | average power used during the period |
B. | average kWh (kW) energy consumption during the period |
C. | either of the above |
D. | none of the above |
Answer» C. either of the above | |
83. |
Different generating stations use following prime movers |
A. | Diesel engine |
B. | Hydraulic turbine |
C. | Gas turbine |
D. | Any of the above |
Answer» E. | |
84. |
A nuclear power plant is invariably used as a |
A. | peak load plant |
B. | base load plant |
C. | stand-by plant |
D. | spinning reserve plant |
E. | any of the above |
Answer» C. stand-by plant | |
85. |
Which of the following component, in a steam power plant, needs maximum maintenance attention? |
A. | Steam turbine |
B. | Condenser |
C. | Water treatment plant |
D. | Boiler |
Answer» E. | |
86. |
Air will not be the working substance in which of the following ? |
A. | Closed cycle gas turbine |
B. | Open cycle gas turbine |
C. | Diesel engine |
D. | Petrol engine |
Answer» B. Open cycle gas turbine | |
87. |
offers the highest electric load. |
A. | Television set |
B. | Toaster |
C. | Vacuum cleaner |
D. | Washing machine |
Answer» C. Vacuum cleaner | |
88. |
Ships are generally powered by |
A. | nuclear power plants |
B. | hydraulic turbines |
C. | diesel engines |
D. | steam accumulators |
E. | none of the above |
Answer» D. steam accumulators | |
89. |
Which of the following should be used for extinguishing electrical fires ? |
A. | Water |
B. | Carbon tetrachloride fire extinguisher |
C. | Foam type fire extinguisher |
D. | CO2 fire extinguisher |
Answer» C. Foam type fire extinguisher | |
90. |
_______ will offer the least load. |
A. | Vacuum cleaner |
B. | Television |
C. | Hair dryer |
D. | Electric shaver |
Answer» E. | |
91. |
The least share of power is provided in India, by which of the following power plants? |
A. | Diesel power plants |
B. | Thermal power plants |
C. | Hydro-electric power plants |
D. | Nuclear power plants |
Answer» B. Thermal power plants | |
92. |
Which of the following generating station has minimum ruiyiing cost ? |
A. | Nuclear |
B. | Hydro |
C. | Thermal |
D. | Diesel |
Answer» C. Thermal | |
93. |
The effect of electric shock on human body depends on which of the following |
A. | current |
B. | voltage |
C. | duration of contact |
D. | all of the above |
Answer» E. | |
94. |
An induction motor has relatively high power factor at |
A. | rated r.p.m. |
B. | no load |
C. | 20 percent load |
D. | near full load |
E. | none of the above |
Answer» E. none of the above | |
95. |
The knowledge of diversity factor helps in determining |
A. | plant capacity |
B. | average load |
C. | peak load |
D. | kWh generated |
E. | none of the above |
Answer» B. average load | |
96. |
Following power plant has instant starting |
A. | nuclear power plant |
B. | hydro power plant |
C. | diesel power plant |
D. | both (B) and (C) |
E. | none of the above |
Answer» E. none of the above | |
97. |
In power plants insurance cover is provided for which of the following ? |
A. | Unskilled workers only |
B. | Skilled workers only |
C. | Equipment only |
D. | All of the above |
Answer» E. | |
98. |
Load shedding is possible through which of the following ? |
A. | Switching of the loads |
B. | Frequency reduction |
C. | Voltage reduction |
D. | Any of the above |
Answer» E. | |
99. |
When the demand of consumers is not met by a power plant, it will resort to which of the following ? |
A. | Load shedding |
B. | Power factor improvement at the , generators |
C. | Penalising high load consumers by increasing the charges for electricity |
D. | Efficient plant operation |
Answer» B. Power factor improvement at the , generators | |
100. |
Submarines for under water movement, are powered by which of the following ? |
A. | Steam accumulators |
B. | Air motors |
C. | Diesel engines |
D. | Batteries |
Answer» E. | |