 
			 
			MCQOPTIONS
 Saved Bookmarks
				This section includes 21 Mcqs, each offering curated multiple-choice questions to sharpen your Environmental Engineering knowledge and support exam preparation. Choose a topic below to get started.
| 1. | The manhole in which vertical pipe is used for the transfer of sewage from branch to main sewer is __________ | 
| A. | Deep manhole | 
| B. | Ramp | 
| C. | Drop manhole | 
| D. | Normal manhole | 
| Answer» D. Normal manhole | |
| 2. | The minimum diameter of the working chamber for a circular manhole is __________ | 
| A. | 0.8m | 
| B. | 0.9m | 
| C. | 1m | 
| D. | 1.2m | 
| Answer» E. | |
| 3. | The thickness of the manhole frame is __________ | 
| A. | 10cm | 
| B. | 15cm | 
| C. | 20cm | 
| D. | 40cm | 
| Answer» D. 40cm | |
| 4. | The manhole in which inclined pipe for transfer of sewage from branch to main sewer is __________ | 
| A. | Deep manhole | 
| B. | Ramp | 
| C. | Drop manhole | 
| D. | Normal manhole | 
| Answer» C. Drop manhole | |
| 5. | The minimum diameter of the access shaft for a circular manhole is __________ | 
| A. | 60cm | 
| B. | 20cm | 
| C. | 30cm | 
| D. | 10cm | 
| Answer» B. 20cm | |
| 6. | The minimum thickness of the side wall of the manhole is __________ | 
| A. | 50mm | 
| B. | 100mm | 
| C. | 225mm | 
| D. | 300mm | 
| Answer» D. 300mm | |
| 7. | THE_THICKNESS_OF_THE_MANHOLE_FRAME_IS?$ | 
| A. | 10cm | 
| B. | 15cm | 
| C. | 20cm | 
| D. | 40cm | 
| Answer» D. 40cm | |
| 8. | The manhole in which vertical pipe is used for the transfer of sewage from branch to main sewer is$ | 
| A. | Deep manhole | 
| B. | Ramp | 
| C. | Drop manhole | 
| D. | Normal manhole | 
| Answer» D. Normal manhole | |
| 9. | The_minimum_diameter_of_working_chamber_for_a_circular_manhole_is$ | 
| A. | 0.8m | 
| B. | 0.9m | 
| C. | 1m | 
| D. | 1.2m | 
| Answer» E. | |
| 10. | Which device is used to prevent the clogging of sewer pipes? | 
| A. | Flushing tank | 
| B. | Drop manhole | 
| C. | Lamp hole | 
| D. | Storm regulators | 
| Answer» B. Drop manhole | |
| 11. | ________ removes oil and grease from the sewage. | 
| A. | Catch basin | 
| B. | Gullies | 
| C. | Grease and oil traps | 
| D. | Storm regulators | 
| Answer» D. Storm regulators | |
| 12. | Which sewer appurtenance is used for removing rainwater from the roads? | 
| A. | Catch basin | 
| B. | Gullies | 
| C. | Lamp hole | 
| D. | Storm regulators | 
| Answer» C. Lamp hole | |
| 13. | Which sewer appurtenance allows lamp in the sewer? | 
| A. | Catch basin | 
| B. | Drop manhole | 
| C. | Lamp hole | 
| D. | Storm regulators | 
| Answer» D. Storm regulators | |
| 14. | The manhole in which inclined pipe for transfer of sewage from branch to main sewer i? | 
| A. | Deep manhole | 
| B. | Ramp | 
| C. | Drop manhole | 
| D. | Normal manhole | 
| Answer» C. Drop manhole | |
| 15. | The minimum diameter of the access shaft for a circular manhole is | 
| A. | 60cm | 
| B. | 20cm | 
| C. | 30cm | 
| D. | 10cm | 
| Answer» B. 20cm | |
| 16. | Into how many types manholes are classified on the basis of depth of manhole? | 
| A. | 3 | 
| B. | 5 | 
| C. | 6 | 
| D. | 7 | 
| Answer» B. 5 | |
| 17. | If the depth of excavation is 4m. What is the thickness of the brick wall of manhole? | 
| A. | 12cm | 
| B. | 16cm | 
| C. | 20cm | 
| D. | 26cm | 
| Answer» E. | |
| 18. | Which of the following is situated above the working chamber in a deep manhole? | 
| A. | Main sewer | 
| B. | Access shaft | 
| C. | Branch sewer | 
| D. | Channel | 
| Answer» C. Branch sewer | |
| 19. | The minimum thickness of the side wall of the manhole is | 
| A. | 50mm | 
| B. | 100mm | 
| C. | 225mm | 
| D. | 300mm | 
| Answer» D. 300mm | |
| 20. | ______ provides the working space for maintenance and inspection of sewers. | 
| A. | Lamp holes | 
| B. | Manholes | 
| C. | Flushing tanks | 
| D. | Working chamber | 
| Answer» E. | |
| 21. | Which of the following is not a sewer appurtenance? | 
| A. | Storm regulator | 
| B. | Flushing tank | 
| C. | Water tank | 
| D. | Manholes | 
| Answer» D. Manholes | |