 
			 
			MCQOPTIONS
 Saved Bookmarks
				This section includes 9 Mcqs, each offering curated multiple-choice questions to sharpen your Heat Transfer knowledge and support exam preparation. Choose a topic below to get started.
| 1. | What is the total number of concurrent flow regime in the given setup of Shell and Tube HE? | 
| A. | 1 | 
| B. | 2 | 
| C. | 3 | 
| D. | 0 | 
| Answer» E. | |
| 2. | What is the total number of counter-current flow regime in the given setup of double split flow? | 
| A. | 1 | 
| B. | 2 | 
| C. | 3 | 
| D. | 4 | 
| Answer» E. | |
| 3. | What is the total number of counter-current flow regime in the given setup of split flow? | 
| A. | 1 | 
| B. | 2 | 
| C. | 3 | 
| D. | 4 | 
| Answer» C. 3 | |
| 4. | In the following shell and tube setup as shown, recognise the number of Concurrent and Counter-current interactions. | 
| A. | 2 concurrent and 4 counter current | 
| B. | 3 concurrent and 3 counter current | 
| C. | 6 concurrent and 0 counter current | 
| D. | 0 concurrent and 6 counter current | 
| Answer» C. 6 concurrent and 0 counter current | |
| 5. | In a shell and tube Heat exchanger, sometimes flow regimes cannot be expressed as concurrent or counter-current. | 
| A. | True | 
| B. | False | 
| Answer» C. | |
| 6. | In a 1-2 Shell and Tube heat exchanger, how many concurrent and counter current flow regimes are observed? | 
| A. | 2 concurrent and 2 counter current | 
| B. | 1 concurrent and 1 counter current | 
| C. | 4 concurrent and 0 counter current | 
| D. | 0 concurrent and 4 counter current | 
| Answer» C. 4 concurrent and 0 counter current | |
| 7. | In the following Figure determine the number of Concurrent flow and Counter-current flow regime. | 
| A. | 2 concurrent and 2 counter current | 
| B. | 1 concurrent and 1 counter current | 
| C. | 2 concurrent and 0 counter current | 
| D. | 0 concurrent and 2 counter current | 
| Answer» C. 2 concurrent and 0 counter current | |
| 8. | In a 2-4 Shell and Tube heat exchanger, how many concurrent and counter current flow regimes are observed? | 
| A. | 2 concurrent and 2 counter current | 
| B. | 1 concurrent and 1 counter current | 
| C. | 4 concurrent and 0 counter current | 
| D. | 0 concurrent and 4 counter current | 
| Answer» B. 1 concurrent and 1 counter current | |
| 9. | In a shell and tube heat exchanger, the flow pattern is usually ________ | 
| A. | Concurrent | 
| B. | Counter current | 
| C. | Concurrent at a part and Counter current at the other | 
| D. | Mixed flow | 
| Answer» D. Mixed flow | |