This section includes 45 Mcqs, each offering curated multiple-choice questions to sharpen your Biomedical Instrumentation knowledge and support exam preparation. Choose a topic below to get started.
1. |
Blood glucose level measurement device uses a biosensor works on the principle of electrochemical. |
A. | True |
B. | False |
Answer» B. False | |
2. |
Home blood glucose measurement devices measure the glucose level through non-invasive method. |
A. | True |
B. | False |
Answer» C. | |
3. |
The chemical reaction of glucose with oxygen is catalyzed in the presence of ________ |
A. | glucose oxidase |
B. | monoglucose carbodase |
C. | glusoce dioxidase |
D. | biglucose oxidase |
Answer» B. monoglucose carbodase | |
4. |
Home blood glucose sensor works on which principle? |
A. | electro-physiological |
B. | electrochemical |
C. | physio-chemical |
D. | chemical |
Answer» C. physio-chemical | |
5. |
Endoscopic imaging uses ___________ |
A. | thermal sensors |
B. | chemical sensors |
C. | optic fiber sensors |
D. | pressure sensors |
Answer» D. pressure sensors | |
6. |
Monopolar needle electrode have a coating of which material over the stainless steel wires which are bare only at the tips? |
A. | carbon |
B. | calcium |
C. | sodium |
D. | teflon |
Answer» E. | |
7. |
For constructing the glucose sensor, which of the following is used as a gel? |
A. | Urea |
B. | Urease |
C. | Acrylamide |
D. | Polyacrylamide |
Answer» E. | |
8. |
In glucose sensor, a measure of change in oxygen value is a measure of the glucose value. |
A. | True |
B. | False |
Answer» B. False | |
9. |
Given below is the diagram of biosensor. Identify the unmarked component. |
A. | Microprocessor |
B. | Filter |
C. | Transducer |
D. | A/D converter |
Answer» D. A/D converter | |
10. |
Nanoscopic optical biosensors have fast response time but the sensitivity is reduced. |
A. | True |
B. | False |
Answer» C. | |
11. |
An example of biosensor, urea electrode makes use of which of the following electrodes? |
A. | Carbon dioxide electrode |
B. | Ammonia electrode |
C. | Fluoride electrode |
D. | Ammonium electrode |
Answer» E. | |
12. |
Which of the following is not a characteristic of the immobilized enzymes? |
A. | They cannot be re-used |
B. | It produces reproducible results |
C. | Stability exists |
D. | Same catalytic activity is present for number of analysis |
Answer» B. It produces reproducible results | |
13. |
In a biosensor ___________ is one which involves subtracting a ‘reference’ baseline signal from the sample signal. |
A. | signal processor |
B. | amplifier |
C. | detector |
D. | transducer |
Answer» B. amplifier | |
14. |
What property of enzyme doesn’t make it an excellent analytical reagent? |
A. | Specificity |
B. | Selectivity |
C. | Piezo-electric biosensor |
D. | Location of the enzyme |
Answer» D. Location of the enzyme | |
15. |
_______________ biosensors are those in which the changes in the distribution of charges causing an electrical potential to be produced. |
A. | Calorimetric |
B. | Potentiometric |
C. | Optical |
D. | Amperometric |
Answer» C. Optical | |
16. |
There are 3 so called generation of biosensors. |
A. | True |
B. | False |
Answer» B. False | |
17. |
Distribution of charges: Potentiometric biosensor:: Mass of reactants or products: _________ |
A. | Optical biosensor |
B. | Calorimetric biosensor |
C. | Piezo-electric biosensor |
D. | Amperometric biosensor |
Answer» D. Amperometric biosensor | |
18. |
When the physical change produced in a biosensor is due to the movement of electrons produced in a redox reaction, the biosensor is referred to as ____________ |
A. | calorimetric biosensor |
B. | potentiometric biosensor |
C. | piezo-electric biosensor |
D. | amperometric biosensor |
Answer» E. | |
19. |
Heat output: calorimetric biosensor:: light output: ____________ |
A. | Optical biosensor |
B. | Piezo-electric biosensor |
C. | Potentiometric biosensor |
D. | Amperometric biosensor |
Answer» B. Piezo-electric biosensor | |
20. |
If the physical change accompanying the reaction is heat output, the biosensors are referred to as _________________ |
A. | potentiometric biosensors |
B. | optical biosensors |
C. | calorimetric biosensors |
D. | amperometric biosensors |
Answer» D. amperometric biosensors | |
21. |
What does the following diagram represent? |
A. | Packed bed reactor |
B. | Schematic diagram showing the main components of a biosensor |
C. | Chromatography |
D. | Lock and key model |
Answer» C. Chromatography | |
22. |
Immobilized enzymes are more preferred over free enzymes in producing biosensors. |
A. | True |
B. | False |
Answer» B. False | |
23. |
Which of the following property is not possessed by biosensors? |
A. | The probe used in the biosensor must be tiny and biocompatible, having no toxic or antigenic effects |
B. | The biosensor should be cheap, small, portable and capable of being used by semi-skilled operators |
C. | There should be a market for the biosensor |
D. | The specificity of substrate binding is mediated by spatial arrangement of atoms in an enzyme’s substrate binding site as well as substrate. |
Answer» E. | |
24. |
Which of the following features is not possessed by biosensor? |
A. | The biocatalyst used in the biosensor must be highly specific for the purpose of the analyses |
B. | The reaction occurring in the biosensor should be as independent of such physical parameters |
C. | Active site is mainly constituted by non-polar amino acids for catalysis to take place |
D. | The response from the biosensors should be accurate, precise, reproducible and linear |
Answer» D. The response from the biosensors should be accurate, precise, reproducible and linear | |
25. |
Which of the following statements is not true for biosensors? |
A. | Biosensors convert a biological signal into an electrical signal |
B. | Biosensors are used to determine the concentration of substances and other parameters of biological interest even where they do not utilize a biological system directly |
C. | Biosensors utilize the different biological systems such as enzymes, whole cell metabolism, ligand binding and the antibody-antigen reaction |
D. | Biosensor consists of a vessel, or series of vessels, used to perform a desired conversion by enzymic means |
Answer» E. | |
26. |
BLOOD_GLUCOSE_LEVEL_MEASUREMENT_DEVICE_USES_A_BIOSENSOR_WORKS_ON_THE_PRINCIPLE_OF_ELECTROCHEMICAL.?$ |
A. | True |
B. | False |
Answer» B. False | |
27. |
NANOSCOPIC_OPTICAL_BIOSENSORS_HAVE_FAST_RESPONSE_TIME_BUT_THE_SENSITIVITY_IS_REDUCED.?$ |
A. | True |
B. | False |
Answer» C. | |
28. |
HOME_BLOOD_GLUCOSE_MEASUREMENT_DEVICES_MEASURE_THE_GLUCOSE_LEVEL_THROUGH_NON-INVASIVE_METHOD.?$ |
A. | True |
B. | False |
Answer» C. | |
29. |
In glucose sensor, a measure of change in oxygen value is a measure of the glucose value.$ |
A. | True |
B. | False |
Answer» B. False | |
30. |
For_constructing_the_glucose_sensor,_which_of_the_following_is_used_as_gel? |
A. | Urea |
B. | Urease |
C. | Acrylamide |
D. | Polyacrylamide |
Answer» E. | |
31. |
Which of the following biosensors use the movement of electrons produced during redox reactions? |
A. | Amperometric biosensor |
B. | Potentiometric biosensors |
C. | Piezo-electric biosensors |
D. | Optical biosensors |
Answer» B. Potentiometric biosensors | |
32. |
The chemical reaction of glucose with oxygen is catalyzed in the presence of _______? |
A. | glucose oxidase |
B. | monoglucose carbodase |
C. | glusoce dioxidase |
D. | biglucose oxidase |
Answer» B. monoglucose carbodase | |
33. |
Which of these biosensors use the principle of heat released or absorbed by a reaction? |
A. | Potentiometric biosensor |
B. | Optical biosensors |
C. | Piezo-electric biosensors |
D. | Calorimetric biosensors |
Answer» E. | |
34. |
Home blood glucose sensor works on the which principle? |
A. | electro-physiological |
B. | electrochemical |
C. | physio-chemical |
D. | chemical |
Answer» C. physio-chemical | |
35. |
Transducers employed in the bulk of enzyme electrodes use which of the following principles? |
A. | Amperometric |
B. | Optical |
C. | Magnetic |
D. | Colorimetric |
Answer» B. Optical | |
36. |
The biological response of the biosensor is determined by ______ |
A. | biocatalytic membrane |
B. | physio-chemical membrane |
C. | chemical membrane |
D. | artificial membrane |
Answer» B. physio-chemical membrane | |
37. |
Biosensors measure glucose concentrations between which of the following ranges? |
A. | 10<sup>-1</sup> to 10<sup>-2</sup> M |
B. | 10<sup>-2</sup> to 10<sup>-4</sup> M |
C. | 10<sup>-1</sup> to 10<sup>-4</sup> M |
D. | 10<sup>-1</sup> to 10<sup>-7</sup> M |
Answer» E. | |
38. |
_______________ converts biochemical events into measurable signals. |
A. | amplifier |
B. | opamp |
C. | rectifier |
D. | transducer |
Answer» E. | |
39. |
In glucose electrode, glucose oxidase has been coupled to an electrode by which of the following materials? |
A. | Ferrocene derivatives |
B. | Urease |
C. | Polyacrylamide |
D. | Biochips |
Answer» B. Urease | |
40. |
Endoscopic imaging uses ___________ |
A. | thermal sensors |
B. | chemical sensors |
C. | optic fiber sensors |
D. | pressure sensors |
Answer» D. pressure sensors | |
41. |
An example of bio sensor, urea electrode makes use of which of the following electrodes? |
A. | Carbon dioxide electrode |
B. | Ammonia electrode |
C. | Fluoride electrode |
D. | Ammonium electrode |
Answer» E. | |
42. |
Monopolar needle electrode are have a coating of which material over the stainless steel wires which are bare only at the tips? |
A. | carbon |
B. | calcium |
C. | sodium |
D. | teflon |
Answer» E. | |
43. |
Which of the following is the physico-chemical component? |
A. | Enzymes |
B. | Anti-bodies |
C. | Transducer |
D. | Cells or tissues |
Answer» D. Cells or tissues | |
44. |
Fluoroptic temperature sensors work on the principle of _______ |
A. | thermistor |
B. | thermocouple |
C. | optical fiber |
D. | rtd |
Answer» D. rtd | |
45. |
Doppler velocimetry works on the principle of __________ |
A. | frequency measurement of fiber optic sensor |
B. | amplitude measurement of fiber optic sensor |
C. | phase measurement of fiber optic sensor |
D. | time shift measurement of fiber optic sensor |
Answer» B. amplitude measurement of fiber optic sensor | |