 
			 
			MCQOPTIONS
 Saved Bookmarks
				This section includes 12 Mcqs, each offering curated multiple-choice questions to sharpen your Enzyme Technology knowledge and support exam preparation. Choose a topic below to get started.
| 1. | In a biosensor ___________ is one which involves subtracting a reference baseline signal from the sample signal. | 
| A. | signal processor | 
| B. | amplifier | 
| C. | detector | 
| D. | transducer | 
| Answer» B. amplifier | |
| 2. | What property of enzyme doesn t make it an excellent analytical reagent? | 
| A. | Specificity | 
| B. | Selectivity | 
| C. | Piezo-electric biosensor | 
| D. | Location of the enzyme | 
| Answer» D. Location of the enzyme | |
| 3. | _______________ biosensors are those in which the changes in the distribution of charges causing an electrical potential to be produced. | 
| A. | Calorimetric | 
| B. | Potentiometric | 
| C. | Optical | 
| D. | Amperometric | 
| Answer» C. Optical | |
| 4. | There are 3 so called generation of biosensors. | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 5. | Distribution of charges: Potentiometric biosensor:: Mass of reactants or products: _________ | 
| A. | Optical biosensor | 
| B. | Calorimetric biosensor | 
| C. | Piezo-electric biosensor | 
| D. | Amperometric biosensor | 
| Answer» D. Amperometric biosensor | |
| 6. | When the physical change produced in a biosensor is due to the movement of electrons produced in a redox reaction, the biosensor is referred to as ____________ | 
| A. | calorimetric biosensor | 
| B. | potentiometric biosensor | 
| C. | piezo-electric biosensor | 
| D. | amperometric biosensor | 
| Answer» E. | |
| 7. | Heat output: calorimetric biosensor:: light output: ____________ | 
| A. | Optical biosensor | 
| B. | Piezo-electric biosensor | 
| C. | Potentiometric biosensor | 
| D. | Amperometric biosensor | 
| Answer» B. Piezo-electric biosensor | |
| 8. | If the physical change accompanying the reaction is heat output, the biosensors are referred to as _________________ | 
| A. | potentiometric biosensors | 
| B. | optical biosensors | 
| C. | calorimetric biosensors | 
| D. | amperometric biosensors | 
| Answer» D. amperometric biosensors | |
| 9. | Immobilized enzymes are more preferred over free enzymes in producing biosensors. | 
| A. | True | 
| B. | False | 
| Answer» B. False | |
| 10. | Which of the following property is not possessed by biosensors? | 
| A. | The probe used in the biosensor must be tiny and biocompatible, having no toxic or antigenic effects | 
| B. | The biosensor should be cheap, small, portable and capable of being used by semi-skilled operators | 
| C. | There should be a market for the biosensor | 
| D. | The specificity of substrate binding is mediated by spatial arrangement of atoms in an enzyme s substrate binding site as well as substrate. | 
| Answer» E. | |
| 11. | Which of the following features is not possessed by biosensor? | 
| A. | The biocatalyst used in the biosensor must be highly specific for the purpose of the analyses | 
| B. | The reaction occurring in the biosensor should be as independent of such physical parameters | 
| C. | Active site is mainly constituted by non-polar amino acids for catalysis to take place | 
| D. | The response from the biosensors should be accurate, precise, reproducible and linear | 
| Answer» D. The response from the biosensors should be accurate, precise, reproducible and linear | |
| 12. | Which of the following statements is not true for biosensors? | 
| A. | Biosensors convert a biological signal into an electrical signal | 
| B. | Biosensors are used to determine the concentration of substances and other parameters of biological interest even where they do not utilize a biological system directly | 
| C. | Biosensors utilize the different biological systems such as enzymes, whole cell metabolism, ligand binding and the antibody-antigen reaction | 
| D. | Biosensor consists of a vessel, or series of vessels, used to perform a desired conversion by enzymic means | 
| Answer» E. | |