Explore topic-wise MCQs in Enzyme Technology.

This section includes 12 Mcqs, each offering curated multiple-choice questions to sharpen your Enzyme Technology knowledge and support exam preparation. Choose a topic below to get started.

1.

In a biosensor ___________ is one which involves subtracting a reference baseline signal from the sample signal.

A. signal processor
B. amplifier
C. detector
D. transducer
Answer» B. amplifier
2.

What property of enzyme doesn t make it an excellent analytical reagent?

A. Specificity
B. Selectivity
C. Piezo-electric biosensor
D. Location of the enzyme
Answer» D. Location of the enzyme
3.

_______________ biosensors are those in which the changes in the distribution of charges causing an electrical potential to be produced.

A. Calorimetric
B. Potentiometric
C. Optical
D. Amperometric
Answer» C. Optical
4.

There are 3 so called generation of biosensors.

A. True
B. False
Answer» B. False
5.

Distribution of charges: Potentiometric biosensor:: Mass of reactants or products: _________

A. Optical biosensor
B. Calorimetric biosensor
C. Piezo-electric biosensor
D. Amperometric biosensor
Answer» D. Amperometric biosensor
6.

When the physical change produced in a biosensor is due to the movement of electrons produced in a redox reaction, the biosensor is referred to as ____________

A. calorimetric biosensor
B. potentiometric biosensor
C. piezo-electric biosensor
D. amperometric biosensor
Answer» E.
7.

Heat output: calorimetric biosensor:: light output: ____________

A. Optical biosensor
B. Piezo-electric biosensor
C. Potentiometric biosensor
D. Amperometric biosensor
Answer» B. Piezo-electric biosensor
8.

If the physical change accompanying the reaction is heat output, the biosensors are referred to as _________________

A. potentiometric biosensors
B. optical biosensors
C. calorimetric biosensors
D. amperometric biosensors
Answer» D. amperometric biosensors
9.

Immobilized enzymes are more preferred over free enzymes in producing biosensors.

A. True
B. False
Answer» B. False
10.

Which of the following property is not possessed by biosensors?

A. The probe used in the biosensor must be tiny and biocompatible, having no toxic or antigenic effects
B. The biosensor should be cheap, small, portable and capable of being used by semi-skilled operators
C. There should be a market for the biosensor
D. The specificity of substrate binding is mediated by spatial arrangement of atoms in an enzyme s substrate binding site as well as substrate.
Answer» E.
11.

Which of the following features is not possessed by biosensor?

A. The biocatalyst used in the biosensor must be highly specific for the purpose of the analyses
B. The reaction occurring in the biosensor should be as independent of such physical parameters
C. Active site is mainly constituted by non-polar amino acids for catalysis to take place
D. The response from the biosensors should be accurate, precise, reproducible and linear
Answer» D. The response from the biosensors should be accurate, precise, reproducible and linear
12.

Which of the following statements is not true for biosensors?

A. Biosensors convert a biological signal into an electrical signal
B. Biosensors are used to determine the concentration of substances and other parameters of biological interest even where they do not utilize a biological system directly
C. Biosensors utilize the different biological systems such as enzymes, whole cell metabolism, ligand binding and the antibody-antigen reaction
D. Biosensor consists of a vessel, or series of vessels, used to perform a desired conversion by enzymic means
Answer» E.